Measurement of Gas Holdup and Mass Transfer in a Bubble Column by Using Electrical Resistance Tomography (ERT)

Journal Title: Jurnal Kejuruteraan - Year 2017, Vol 29, Issue 2

Abstract

Gas dispersion performance and gas hold-up in a bubble column was investigated by using electrical resistance tomography (ERT). Experiments were carried out to visualize flow pattern and gas hold-up at different gas velocity, type of impeller and speed of impeller. In this study, cylindrical bubble-column with a diameter of 13.5 cm and a height of 97.5 cm, made of glass that was mounted with four planes of 16 stainless steel electrodes are connected to an ITS P2000 ERT system. The column was equipped with perforated plate consisting of five holes and each has internal diameter of 3.0 mm. The effect of four parameters; gas flowrate, speed of impeller, 2 types of impeller; Rushton and Lightnin impeller, and three types of gas; oxygen, hydrogen and nitrogen gas on the gas dispersion performance in the bubble column were investigated. It was observed that the gas dispersion rate is increased with increasing gas density where the oxygen gas has the highest of dispersion gas rate as compared to the others gas. The gas hold-up was determined from the correlation method to estimate the transition velocity and dispersion of gas in a bubble column. The results showed that with increasing of the superficial gas velocity, the total gas hold-up increases. Besides, the gas hold-up increased due to decreasing of gas density. It can be concluding that the optimum mixing condition was obtained by using Lightnin A320 impeller with the speed rate at 250 rpm.

Authors and Affiliations

Nur Tantiyani Ali Othman, Nur Syamimi Wahid

Keywords

Related Articles

Flow Behavior of 1.4841 Steel in Hot Compression Process

Hot compression experiments using a dilatometer were carried out in order to study the effects of hot compression parameters on the flow behaviour of 1.4841 steel. Specifically, the effects of the strain rate and the def...

Vortex Measurement at Bell-Shaped Pump Inlet Using Particle Image Velocimetry

The vortex formed at the pump intake is known to be the main factor affecting the performance of a pump and it contributes directly to the increase of energy consumption. This study was aimed at obtaining an in-depth vis...

Car Driver Attitude towards Road Safety Measures

Road traffic accidents (RTA) constituted a severe public problem in all countries of the world. Roughly about 1.5 million people around the world die in traffic-related accidents. Its absolute impact is exacerbated by th...

Pemodelan Hubungan Antara Kualiti Perkhidmatan, Kesan Alam Sekitar, Sikap dan Keinginan untuk Menggunakan Park-and-Ride (Modelling of Relationship Between Service Quality, Environmental Impact, Attitude and Intention to Use Park-and-Ride)

Structural equation modelling (SEM) is a modelling technique that can handle a large number of endogenous and exogenous variables, as well as latent variables specified as linear combinations of the observed variables. U...

Analisis Ramalan Pelemahan Hujan Semenanjung Malaysia Menggunakan PetaRekaan Berkontur (Rain Attenuation Prediction of Peninsular Malaysia using Contour Map)

Hujan melemahkan isyarat gelombang mikro melalui proses penyerapan dan penyelerakan menyebabkan penerimaan isyarat mengalami gangguan pada sistem satelit yang beroperasi melebihi frequensi 10 GHz. Fenomena ini menyebabka...

Download PDF file
  • EP ID EP417653
  • DOI 10.17576/jkukm-2017-29(2)-07
  • Views 94
  • Downloads 0

How To Cite

Nur Tantiyani Ali Othman, Nur Syamimi Wahid (2017). Measurement of Gas Holdup and Mass Transfer in a Bubble Column by Using Electrical Resistance Tomography (ERT). Jurnal Kejuruteraan, 29(2), 113-119. https://europub.co.uk/articles/-A-417653