Measurement of Radiation Abutment Dose for 6MV Photon and 9 MeV Electron Beam Combinations by GAFCHROMIC EBT3 Film at Extended SSD

Abstract

To measure the radiation abutment dose for 6 mega voltage (MV) photon and 9 mega electron volt (MeV) electron beam combinations by gafchromic EBT3 film at extended source to skin distance (SSD). A point dose measurement was done to calculate monitor for delivering 100 cGy dose at 3cm depth in RW3 solid water phantom for 9 MeV electron beam. for 110 cm and 120 cm SSDseparately . Monitoring units (MU) were calculate to deliver a point dose of 50 cGy at 6 cm depth by 6 MV asymmetric beam. Plans were delivered separately on RW3 solid water phantom having gafchromic EBT3 film strips placed at 1, 2 and 3 cm depths. Followed by generating the calibration curve for EBT3 gafchromicfim, profiles at the abutment regions were analyzed by dosimetry software (FimQa pro, version 3.0, Ashland, USA). The value of hot spot and cold spot has increased with increasing electron beam SSD from 110 cm to 120 cm. Maximum value of hot spot for 110 and 120 cm SSD was 141.6% and 146.235 respectively at 2 cm depth whereas maximum value of the cold spot was 76.24% and 72.8% at 3 cm depth. Measurement of the abutment dose in extended SSD of electron beam needs to be evaluated for the adequate dose delivery to the patients in head and cancer as significant hot and cold spot has been observed.

Authors and Affiliations

Vinod Pandey, Lalan Prasad, Kailash Chandra Pandey

Keywords

Related Articles

Revenue and Profit Maximization of Intermediary by Providing Multiple Cloud Services to Users

Data streaming with various cloud condition is a potential response for give the profitable pay on demand respond in due order regarding tradeoff between whole deal leasing and contrasting burdens. In this paper, we pro...

Energy Management in Mobile Devices with the Cinder Operating System

We present Cinder, an operating system for mobile phones and devices, that allows users and applications to control and manage limited device resources such as energy. We argue that controlling energy allocation is an i...

Design and Analysis of Car Disc Brake by Using FEM

Braking is a process which converts the kinetic energy of the vehicle into mechanical energy which must be dissipated in the form of heat. The disc brake is a device for deaccelerating or stopping the rotation of a whee...

Analysis and Comprehensive Study: Image Segmentation Techniques

Image Segmentation plays a vital role in extracting image information from dull and noisy images. Further, image segmentation is the key step in processing images of different types. In last two decades, image segmentat...

Overview and Recent Advancements in Composite Materials

A continuing trend in material development is the evolution of composite materials. The composite materials being very strong and stiff, yet light in weight provide high strength to weight and stiffness to weight ratios...

Download PDF file
  • EP ID EP24342
  • DOI -
  • Views 291
  • Downloads 11

How To Cite

Vinod Pandey, Lalan Prasad, Kailash Chandra Pandey (2017). Measurement of Radiation Abutment Dose for 6MV Photon and 9 MeV Electron Beam Combinations by GAFCHROMIC EBT3 Film at Extended SSD. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 5(5), -. https://europub.co.uk/articles/-A-24342