MEASURING SYSTEM FOR IN VIVO MULTICHANNEL NEURAL SIGNALS RECORDING

Abstract

This paper describes a system for recording neural signals from the brain of the animal under anesthesia. The system allows for simultaneous measurement of signals from 64 points by means of penetrating microelectrode matrix. It consists of dedicated integrated circuit for signal amplification and filtering, power supply module and control module. Dedicated data acquisition is performed using PXI (PeripheralComponent Interconnect eXtensions for Instrumentation) computer and a custom application. Preliminary tests conducted with action potentials simulating signals provided through the electrodes and saline show that the system operates properly.

Authors and Affiliations

Jacek Rauza, Mirosław Żołądź, Piotr Kmon, Paweł Gryboś

Keywords

Related Articles

WPŁYW TYPU PRZEKŁADKI NA TRANSMISJĘ ZŁOŻENIA DWÓCH STRUKTUR BINARNYCH

W pracy przedstawiono metody symulacji transmisji układów wielowarstwowych oraz zbadano wpływ zmiany typu oraz grubości warstwy materiału rozdzielającego dwie struktury wielowarstwowe. Do analizy wykorzystano metodę maci...

IMAGE ANALYSIS METHODS – ANALYSIS OF MAMMOGRAPHIC IMAGE BASED ON TEXTURAL FEATURES

This paper presents an analysis of the possibility of using textural features for mammographic images classification. Textural features are calculated base on histogram, gradient matrix, run-length matrix, co-occurence m...

WYSZUKIWANIE REGIONÓW DO OSADZENIA ZNAKÓW WODNYCH Z WYKORZYSTANIEM ‘PIXEL IMPACT FACTOR’ ORAZ KWANTYZACJI W DZIEDZINIE PRZESTRZENNEJ

W tym artykule proponuję nowe podejście do wyszukiwania regionów do osadzania znaku wodnego w obrazie. Osadzanie wykonywane jestw dziedzinie przestrzennej, z użyciem metod kwantyzacji. Użycie różnych poziomów kwantyzacji...

OPTIMIZATION OF CONTROLLED EXPLOSION PROCESSES PARAMETERS USING COMPLEX ANALYSIS METHODS

The optimal charge power and position necessary for forming the maximum possible size of the crater along with preservation of the integrity of the two nearby objects with the numerical quasiconformal mapping methods wit...

AUTOMATED NMR-RELAXOMETRY FOR CONTROL OF PRODUCTION AND QUALITY

In this work we show the possibility of using of nuclear magnetic resonance at low magnetic fields for the purpose of establishing a system of automated process of control and quality of dairy products.

Download PDF file
  • EP ID EP59356
  • DOI -
  • Views 126
  • Downloads 0

How To Cite

Jacek Rauza, Mirosław Żołądź, Piotr Kmon, Paweł Gryboś (2012). MEASURING SYSTEM FOR IN VIVO MULTICHANNEL NEURAL SIGNALS RECORDING . Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska, 2(3), 51-53. https://europub.co.uk/articles/-A-59356