Modeling performance in reverse osmosis wastewater treatment post-trial coke in the integrated systems based on the assumptions of the relaxation model
Journal Title: Civil and Environmental Engineering Reports - Year 2011, Vol 1, Issue 6
Abstract
The paper presents the results of studies on coking wastewater, coming from the coke plant "Koksownia Czestochowa Nowa" in two integrated systems associating coagulation volume and advanced oxidation with reverse osmosis. The process of coagulation were performed using iron sulfate (III), (PIX 113) of 400 mg/dm3 and wastewater acidity at pH = 9. The second processes – advanced oxidation was carried out using Fenton's reagent. The concentration of iron (II) was 0.8 g/dm3 and hydrogen peroxide 2.4 g/dm3. Coke post-process water after its initial treatment was subjected to high-pressure membrane filtration. In the process of reverse osmosis a flat polyamide membrane ADF of Osmonics was used. Transmembrane pressure was 2 MPa and the linear speed of water on the membrane surface of 2m/s. Comparison of the effectiveness of wastewater treatment in both tested systems has shown that the system combining the advanced oxidation with reverse osmosis is more effective. In addition, this study attempts to model effectiness of the process of reverse osmosis in both studied systems, based on the assumptions of a relaxation model. An experimentally determined dependence of changes in volume of treated wastewater fluxes from the time of the high-pressure membrane filtration, and the values of time constant efficiency of the process characterized by a decrease to below economic viability allowed us fo verify this model.<br/><br/>
Authors and Affiliations
K. Mielczarek, J. Bohdziewicz, A. Kwarciak-Kozłowska
TECHNOLOGICAL MOISTURE AS A CAUSE OF MOULDS ON BUILDING PARTITIONS
The intense pace of construction work means that technical materials contain so-called technological moisture, which enables the development of biodeteriogenic organisms on building partitions. This article presents the...
PRELIMINARY ANALYSIS OF THE ALUMINIUM-TIMBER COMPOSITE BEAMS
This paper presents a new type of composite structures - aluminium-timber beams. These structures have an advantage over other existing composite structures, because they are lighter. However, their application may be li...
Profesor Krzysztof Wilmański on his 70th birthday
Reliability of a building determined by the durability of its components
The conviction that the relation between the durability of elements and the methodology of renovation prediction is worth investigating results from the search of efficient methods of maintenance planning in buildings er...
Two-scale modelling of reactive powder concrete. Part I: representative volume element and solution of the corresponding boundary value problem
The article is the first part of a series concerned with the modelling of reactive powder concrete by using a numerical homogenization technique. This technique is a multi-scale modelling approach. Specifically, in this...