MODERNIZATION OF FLUX-GATE MAGNETOMETER

Abstract

Various types of magnetic field sensors, their advantages and disadvantages are considered. Classic flux-gate magnetometer, the block diagram of which is driven, contains dualcore sensor with counter switching of primary magnetization coil and general output secondary coil for both cores. The disadvantage of this sensor – the complexity of manufacturing and the need for precise balancing of magnetization coil. The single-core sensor is suggested. It differs from the counterpart by that the magnetizing coil are powered by amplitude modulated alternating current. Theoretical analysis of the work of upgraded sensor. High-frequency components of the magnetic flux are destroyed due to Foucault currents, therefore on the secondary coil, which is part of the oscillating circuit, a signal with double modulating frequency is released. The block diagram of single-core magnetometer sensor and two generators is driven. The construction of sensor is described and winding data, necessary for its implementation, is provided. The experimental voltage waveforms of the sensor output in measuring the Earth's magnetic field in the direction of north-south and east-west are driven. The features of upgraded magnetometer are comparable with the characteristics of its analog. The advantages of the new device is more simple sensor that does not require precise balancing and the use of high-frequency ferromagnetic materials.

Authors and Affiliations

Yuriy Bobalo, Myroslav Kiselychnyk, M. Melen, F. Pavlov

Keywords

Related Articles

DETERMINATION OF CURRENT SETTING TIME IN INDUCTIVE LOAD OF VOLTAGE-TO-CURRENT CONVERTER UNDER NON-HARMONIC INFLUENCE

The paper presents analysis of problems dealing with the determination of the current setting time in the inductive component of the complex load of Voltage-to-current (VTC) converter under non-harmonic input influence....

FORMATION SERVICE AREA OF THE TRANSCEIVER STATION DEPENDING ON THE VARYING INPUT LOAD

The method of managing energy saving in maintaining a subscriber load by a group of service nodes of access to the network, to provide a service process at a given level of quality in the conditions of multi-channel serv...

Flicker-noise spectroscopy method

Method of determining the processes that take place inside the investigated system is presented here. Method is based on the analysis of energy spectrum of investigated system own noises. Using energy spectrum of own noi...

ENSURING THE STABILITY OF VOLTAGE-TO-CURRENT CONVERTER WITH COMPLEX LOAD

In this paper, the method of determining the stability of the voltage-to-current converter (VCC) with complex load, which is built on the DC amplifier with a deep negative feedback (NFB) by current. The feedback signal i...

METHOD OF SMOOTHING INPUT LOAD ON THE ONLINE CHARGING SYSTEM

Charging users for a server operator billing involves performing a number of operations. Each service provided by the operator or service provider customers, charged at a separate scheme, as the bottleneck in the process...

Download PDF file
  • EP ID EP456367
  • DOI -
  • Views 109
  • Downloads 0

How To Cite

Yuriy Bobalo, Myroslav Kiselychnyk, M. Melen, F. Pavlov (2017). MODERNIZATION OF FLUX-GATE MAGNETOMETER. Вісник Національного університету "Львівська політехніка", серія "Радіоелектроніка та телекомунікації", 885(2017), 3-7. https://europub.co.uk/articles/-A-456367