MODIFICATIONS OF DIODE RECTIFIER CIRCUITS FOR CONTINUOUS INSULATION MEASUREMENT IN LIVE AC IT NETWORKS

Abstract

Purpose. In the paper there are described few systems of insulation resistance continuous measurement using an imposed DC test signal delivered by diode rectifiers. Drawbacks of this technique are pointed out and ways of these shortcomings removal are proposed. Methodology. An improved version of measuring circuit based on a single-phase diode rectifier is presented. Application of logometric measuring devices is suggested. Results. A new insulation resistance continuous measuring system is insensitive to network voltages variation and asymmetry. Modified circuit enables also implementation of a simple device for alarming the monitored network’s insulation deterioration and/or earth-fault protection. Originality. Formulas describing performance of diode rectifiers under asymmetrical supply have not been available so far. Both innovations (i.e. single-phase diode rectifier and logometric meter) have not been applied widely for implementation of continuous insulation monitoring in live AC IT networks. Practical value. Use of both innovations will allow to eliminate unrequired dependence of measurement results on variable network voltages as well as their possible asymmetry. Exploitation of diode rectifier circuits for earth fault location is also possible.

Authors and Affiliations

P. Olszowiec

Keywords

Related Articles

THE EXCITED LOADS OF ATTRACTION IN A SYMMETRICAL INDUCTOR SYSTEM FOR THE MAGNETIC PULSE REMOVING OF THE BODY CAR

Recently, repair and recovery of vehicle body operations become more and more popular. A special place here is taken by equipment that provides performance of given repair operations. The most interesting are methods for...

AN ANTHOLOGY OF OUTSTANDING ACHIEVEMENTS IN SCIENCE AND TECHNOLOGY. PART 18: ROCKET ENGINEERING AND NEAR-SPACE EXPLORATION

A brief scientific and historical essay on the history of designing rocket technology and exploring near and outer space around the Earth is given.

CHARACTERISTICS OF SPECIALIZED SINGLE-PHASE HIGH VOLTAGE DOUBLER RECTIFIER

Introduction. To obtain a high voltage direct current, voltage multipliers with a number of cascades of three or more are widely used. At the same time, for voltage levels of 100…200 kV there are several advantages of us...

QUANTUM-WAVE NATURE OF ELECTRIC CURRENT IN A METALLIC CONDUCTOR AND SOME OF ITS ELECTROPHYSICAL MACRO-PHENOMENA

The paper presents results of theoretical and experimental research on wave longitudinal and radial distribution of drifting free electrons in a round homogeneous metallic conductor with a pulse axial current. The studie...

A NEW ROBUST CONTROL USING ADAPTIVE FUZZY SLIDING MODE CONTROL FOR A DFIG SUPPLIED BY A 19-LEVEL INVERTER WITH LESS NUMBER OF SWITCHES

This article presents the powers control of a variable speed wind turbine based on a doubly fed induction generator (DFIG) because of their advantages in terms of economy and control. The considered system consists of a...

Download PDF file
  • EP ID EP290732
  • DOI 10.20998/2074-272X.2016.2.08
  • Views 106
  • Downloads 0

How To Cite

P. Olszowiec (2016). MODIFICATIONS OF DIODE RECTIFIER CIRCUITS FOR CONTINUOUS INSULATION MEASUREMENT IN LIVE AC IT NETWORKS. Електротехніка і Електромеханіка, 0(2), 43-46. https://europub.co.uk/articles/-A-290732