Monte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator

Journal Title: Journal of Biomedical Physics and Engineering - Year 2019, Vol 9, Issue 2

Abstract

Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams. Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosimetric features including lateral profiles, central axis depth dose, photon and electron spectra were calculated for flattened and unflattened cases, separately. Results: An increase in absolute depth dose with a factor of more than 2.4 was observed for unflattened beam which was dependent on depth. PDDs values were found to be lower for unflattened beam for all field sizes. Significant decrease in calculated mlc leakage was observed when the flattening filter was removed from the beam line. The total scatter factor, SCP was found to show less variation with field sizes for unflattened beam indicating a decrease in head scatter. The beam profiles for unflattened case are found to have lower relative dose value in comparison with flattened beam near the field edge, and it falls off faster with distance. Conclusion: Our study showed that increase in the dose rate and lower peripheral dose could be considered as realistic advantages for unflattened 6MV photon beams.

Authors and Affiliations

A. Kajaria, N. Sharma, Sh. Sharma, S. Pradhan, L. M. Aggarwal L. M.

Keywords

Related Articles

In-silico Evaluation of Rare Codons and their Positions in the Structure of ATP8b1 Gene

Background: Progressive familial intrahepatic cholestases (PFIC) are a spectrum of autosomal progressive liver diseases developing to end-stage liver disease. ATP8B1 deficiency caused by mutations in ATP8B1 gene encoding...

Correlation between Trunk-Pelvis InterSegmental Coordination Parameters during Walking and Disability Level in Chronic Low Back Pain Patients

Background: Chronic low back pain (CLBP) disability has been particularly frustrating because its treatment has been a great therapeutic challenge. Disability has been suggested to depend on different factors that should...

Determining Changes in Electromyography Indices when Measuring Maximum Acceptable Weight of Lift in Iranian Male Students

Background: In spite of the increasing degree of automation in industry, manual material handling (MMH) is still performed in many occupational settings. The aim of the current study was to determine the maximum acceptab...

Effect of Exercise Training on Heart Rate Variability in Patients with Heart Failure After Percutaneous Coronary Intervention

Background: This study aims to evaluate the effect of exercise training on heart rate variability (HRV) and to determine the correlation between parameters of HRV and the ejection fraction in patients with heart failure...

Download PDF file
  • EP ID EP613411
  • DOI -
  • Views 90
  • Downloads 0

How To Cite

A. Kajaria, N. Sharma, Sh. Sharma, S. Pradhan, L. M. Aggarwal L. M. (2019). Monte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator. Journal of Biomedical Physics and Engineering, 9(2), 137-150. https://europub.co.uk/articles/-A-613411