AN OVERVIEW ON FOURIER TRANSFORM MASS SPECTROMETRY
Journal Title: Int J of Preclin & Pharm Res - Year 2014, Vol 4, Issue 5
Abstract
ABSTRACT This article provides an introduction to Fourier transform-based mass spectrometry. The key performance characteristics of Fourier transform-based mass spectrometry, mass accuracy and resolution, are presented in the view of how they impact the interpretation of measurements in proteomic applications. The theory and principles of operation of two types of mass analyzer, Fourier transform ion cyclotron resonance and Orbitrap, are described. Major benefits as well as limitations of Fourier transform-based mass spectrometry technology are discussed in the context of practical sample analysis, and illustrated with examples included as figures in this text and in the accompanying slide set. Comparisons highlighting the performance differences between the two mass analyzers are made where deemed useful in assisting the user with choosing the most appropriate technology for an application. Recent developments of these high-performing mass spectrometers are mentioned to provide a future outlook. Keywords: Mass spectrometry, Orbitrap, Laser desorption, Analyzers.
Authors and Affiliations
Lakshmidurga K*1, Ram Mohan Reddy. T1, Ajitha. A1, Uma Maheswara Rao. V1
ASSAY METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF PAROXETINE AND CLONAZEPAM BY RP- HPLC
ABSTRACT A simple, precise, rapid, specific and accurate reverse phase high performance liquid chromatography method was developed for simultaneous estimation of Paroxetine and Clonazepam in pharmaceutical dosage...
A REVIEW ON ANALYTICAL METHOD DEVELOPMENT AND VALIDATION
ABSTRACT Analytical methods development must be validated to provide reliable data for regulatory submissions. Method development is the process of proving that an analytical method is acceptable for use to measu...
UTILITY OF ORAL AND VAGINAL MISOPROSTOL IN THE INDUCTION OF LABOUR: A COMPARATIVE STUDY
ABSTRACT This study was conducted to compare the efficiency and safety of oral (50 μg) and vaginal (25 μg) misoprostol for labour induction. In this study one Hundred patients with indications for labour inductio...
DEVELOPMENT AND VALIDATION OF NEW RP-HPLC METHOD FOR CEFTIBUTEN IN BULK AND ITS PHARMACEUTICAL DOSAGE FORM
ABSTRACT A simple, precise, rapid and accurate reverse phase HPLC method has been developed for the determination of Ceftibuten in bulk and its pharmaceutical dosage form. An enable C18G, 250mmX4.6mm i.d, 5µm par...
PHASE SOLUBILITY STUDY OF HYDROPHOBIC DRUG DOMPERIDONE USING A NOVEL TECHNIQUE INCLUSION COMPLEX WITH β-CYCLODEXTRINE
ABSTRACT An inclusion complex of with a β-cyclodextrine and hydroxy propyl cellulose is a convenient new technique for enhancing the solubility of Domperidone. Phase-solubility studies demonstrated the ability o...