DESIGN AND ANALYSIS OF FEMORAL NAIL EXTRACTION INSTRUMENT FOR HUMAN FEMUR BONE

Abstract

 Different conventional techniques have been noticed to remove intramedullary femur distal nail, a simple method is explained to remove a broken distal closed section intramedullary nail with nail extraction instrument. The surgical technique is described. This technique reduces physical torture of patient during surgery and headache of doctors. In this article the design procedure for nail extraction instrument is explained as well as analysis results (in ANSYS) of nail extraction instrument are discussed. This technique involves removal of distal broken femur nail by on the spot creating threads in the nail, which is one of the feasible technique & the results of this analysis are helpful for orthopedic surgeons for clinical interest.

Authors and Affiliations

A. G. Pawar

Keywords

Related Articles

PAIRED FASTER FFT: GRIGORYAN FFT IMPLEMENTATION AND PERFORMANCE ON XILINX FPGAS AND TMS DSPS

Discrete Fourier Transform is a principal mathematical method for the frequency analysis and has wide applications in Engineering and Sciences. Because the DFT is so ubiquitous, fast methods for computing DFT have been...

Isolation, Identification and Characterization of Thermo-tolerant Bacteria from Hot- Spring that can degrade Halogenated Compounds

To investigate the microbial community in the hot spring of Krabi, Thailand and if they can degrade some halogenated compounds. A thermophilic bacterium (YKH) was isolated from the Krabi hot spring in Thailand. The isol...

 Analysis of Performance Matrices of OLSR, AOMDV & ZRP Protocols in the VANET Scenario

 Vehicular Ad-Hoc Network (VANET) is a wireless technology which can be integrated into the vehicles. VANET is the sub class of the Mobile Ad-Hoc Networks (MANET). The basic motivation behind the idea is to provid...

 SYNTHESIS OF LEAD SELENIDE WITH SURFACTANT (SDS) BY HYDROTHERMAL METHOD

 Lead Selenide nano cubes were synthesized by using convenient lead soruce i.e., lead acetatate along with Sodium dodecyl sulfate (SDS) as a surfactant by a simple hydrothermal technique. The as prepared nanopartic...

 OFDM-DCT ROBUST CHANNEL SIMULATION

 Multi-Carrier Modulation is a technique for data-transmission by dividing a high-bit rate data stream is several parallel low bit-rate data streams and using these low bit-rate data streams to modulate several car...

Download PDF file
  • EP ID EP107251
  • DOI 10.5281/zenodo.155093
  • Views 57
  • Downloads 0

How To Cite

A. G. Pawar (30).  DESIGN AND ANALYSIS OF FEMORAL NAIL EXTRACTION INSTRUMENT FOR HUMAN FEMUR BONE. International Journal of Engineering Sciences & Research Technology, 5(9), 671-676. https://europub.co.uk/articles/-A-107251