DESIGN AND ANALYSIS OF FEMORAL NAIL EXTRACTION INSTRUMENT FOR HUMAN FEMUR BONE

Abstract

 Different conventional techniques have been noticed to remove intramedullary femur distal nail, a simple method is explained to remove a broken distal closed section intramedullary nail with nail extraction instrument. The surgical technique is described. This technique reduces physical torture of patient during surgery and headache of doctors. In this article the design procedure for nail extraction instrument is explained as well as analysis results (in ANSYS) of nail extraction instrument are discussed. This technique involves removal of distal broken femur nail by on the spot creating threads in the nail, which is one of the feasible technique & the results of this analysis are helpful for orthopedic surgeons for clinical interest.

Authors and Affiliations

A. G. Pawar

Keywords

Related Articles

 SEISMIC EVALUATION OF REINFORCED CONCRETE BUILDING

 In the study of evaluation for retrofitting of any building made up of reinforced concrete is done by using method of inelastic method, capacity curve method etc. Capacity curve which is load deformation plot is o...

DESIGN AND DEVELOPMENT OF MOTHER MOULD OF HYDRAULIC PRESS

Accurate die fixing is an important stage of the hydraulic press with the precised value of clearance. At present the hydraulic press depend on the fixing of die inside the moul d cavity with help of mechanical wedges...

 High-Speed Pool of Aggregated Data in Multi-hop Wireless Network

 Data aggregation is a key functionality in wireless sensor networks (WSNs). Focuses on data aggregation scheduling problem to minimize the delay (or latency). The project proposes an efficient distributed algorith...

 MODELING, DESIGN, AND CONTROL OF ASYNCHRONOUS BUCK CONVERTER FOR MOBILE APPLICATION

 The aim of this paper is to model and design an open-loop and close-loop asynchronous Buck switching converter for mobile applications. The design of the converter is performed to step-down the input voltage 12V t...

 Thermodynamic Analysis of Cogeneration Power Plant

 The aim of this work is to use the energy analysis based on the first law of thermodynamics to identify the locations and magnitudes of losses in order to maximise the performance of a 25 MW plant at Saukem Ltd.,...

Download PDF file
  • EP ID EP107251
  • DOI 10.5281/zenodo.155093
  • Views 61
  • Downloads 0

How To Cite

A. G. Pawar (30).  DESIGN AND ANALYSIS OF FEMORAL NAIL EXTRACTION INSTRUMENT FOR HUMAN FEMUR BONE. International Journal of Engineering Sciences & Research Technology, 5(9), 671-676. https://europub.co.uk/articles/-A-107251