Effect of Evaporative Cooling on Air Conditioning Test Rig

Abstract

 In this manuscript, we tries to prove that the size of air conditioner and power consumption by air conditioner can reduce by provide the effect of evaporative cooling on condenser. So, In our experiment we obtained the Coefficient of performance of air conditioning test rig and condition of air supplied by air conditioning test rig without evaporative then obtained the Co-efficient of performance of air conditioning test rig and condition of air supplied by air conditioning test rig. After find out the result in both cases, we compared both results and calculated the effect of evaporative cooling on air conditioning test rig with the help different parameters such temperature and pressure at different location, refrigerant flow rate, outlet air condition by D.B.T and W.B.T, wattmeter reading etc. We mentioned these results on P-h diagram and Psychrometric chart for better understanding. During our experiment we sprayed water on condenser at the rate of 500 ml/17 Minutes.

Authors and Affiliations

Mohit Yadav

Keywords

Related Articles

 POLYMER STRUCTURES: STUDIES ON THERMAL AND MICROBIALREACTIVITY OF COPOLYMERS AND TERPOLYMERS OF [AZO-N-4-BROMOPHENYL] SUBSTITUTED MALEIMIDE CHAIN WITH ACRYLATES \VINYLS

 We report the synthesis, characterization, thermal and microbial properties of a series of [4-N-Phenylethanamideazo-3-N-(4-Bromophenyl)Maleimide-co-Acrylonitrile] [C1-PAMI-B], [4-N-Phenylethanamide azo-3-N-(4-Bromo...

ONLINE CAREER GUIDANCE SYSTEM

Online Career Guidance System is a web based application which can be accessed throughout the specified department to handle the various processes involved in Career Guidance system. A Career Guidance System where stud...

 Three Phase Power Factor Correction Using SEPIC In DCM With Isolation

 The improvement of power quality are required in AC-DC converters in terms of power factor correction. The PF is improved by reduction of total harmonic distortion at input of ac supply. Also high PF needed precis...

 Effect of Process Variables on the Production of Biodiesel by the Non-Catalytic Supercritical Trans-Esterification of Sheanut Oil

 The production and characterization of biodiesel from sheanut oil was carried out using the supercritical transesterification process and the effects of process variables such as temperature, feed blending ratio,...

NOVEL DESIGN PARAMETERS FOR CMOS LOW NOISE AMPLIFIER

This paper presents the study of different important parameters which are considered for LNA design. Input/output matching, noise figure, Stability, Bandwidth, Gain, Power dissipation and Linearity are the key factors o...

Download PDF file
  • EP ID EP132697
  • DOI -
  • Views 52
  • Downloads 0

How To Cite

Mohit Yadav (30).  Effect of Evaporative Cooling on Air Conditioning Test Rig. International Journal of Engineering Sciences & Research Technology, 3(9), 542-546. https://europub.co.uk/articles/-A-132697