Implementation and Analysis of Modified Double Precision Interval Arithmetic Array Multiplication
Journal Title: International Journal of Computer & organization Trends(IJCOT) - Year 2012, Vol 2, Issue 2
Abstract
This paper presents the design of a 64 bit array multiplier that performs interval multiplication. This multiplier requires carry save adders instead of full adders that reduces the delay i n r e s p e c t o f conventional array multiplier. The 64 bit multiplication requires 53 x 53 multiplication which is done by array multiplier it has n*(n-1) CSA, where n=53 so, n*(n-1) = 53 *52= 2756 CSA is used. Arrangement of 2756 CSA is used to add partial products of multiplier. This multiplier is based on interval arithmetic which provides the better accuracy, b y removing rounding off error over conventional floating point multiplier. There is performance improvement over software implementation of interval arithmetic, but it requires slightly more area rather than conventional floating point unit
Authors and Affiliations
Krutika Ranjan Kumar Bhagwat#1 , Prof. Tejas V. Shah *2 , Prof. Deepali H. Shah#3
Breast Cancer Detection In Mammogram Images Using Region-Growing And Contour-Based Segmentation Techniques
An increase in the use of computers to improve human-to-humanand human-to-computer interaction has necessitated automated methods that extract information on human behavior in an efficient manner. Technology has highly i...
Gradation of NGO’s Role in Rural Development: A Fuzzy Soft Set Theoretic Approach
The non-governmental organizations (NGO) are recognized as important institutional actors that are expected to facilitate the participation of beneficiaries in the development programmes such as mobilising communit...
Power Efficient Weighted Modulo 2n+1 Adder
The comparison of three different architectures for modulo 2n+1 adders are introduced in this paper. The first two architecture can be implemented different power consumptions, while maintain the same delay. The partitio...
An Automatic Detection and Assessment of Diabetic Macular Edema A long With Fovea Detection from Color Retinal Images
Diabetic macular edema (DME) is an advanced symptom of diabetic retinopathy which lead to vision loss. Here a methodology comprises of two stages is proposed. First stage is detecting of DME and the next stage is assessi...
Impact Analysis of Modulation Formats in 40 Gbit/s DWDM Systems
The development of digital optical communications systems at high flow rates (NX40Gbit/s) and wavelength division multiplexed (WDM) reveals new issues such as the need to compensate the chromatic dispersion at higher lev...