INFLUENCE OF TEMPERATURE AND pH ON CORROSION BEHAVIOR OFNI–CR AND CO-CR DENTAL ALLOYS

Journal Title: Journal of International Dental and Medical Research - Year 2013, Vol 6, Issue 1

Abstract

 The aim of this study was to evaluate the influence of temperature and pH on corrosion resistance of Ni-Cr and Co-Cr dental alloys used for fixed and removable partial dentures using potentiodynamic polarization and surface analysis by scanning electron microscopy. The three materials analyzed were Ni-Cr and Co-Cr dental alloys: Kera NH®, Kera 501® and PD Casta H®, which were tested in Fusayama-Meyer artificial saliva with different values of temperature and pH. Our results have shown that Kera 501® and PD Casta H® alloys , which contain Co and a high Cr content, shows the best corrosion resistance in Fusayama-Meyer artificial saliva compare with that of Kera NH® alloy. In acidifid saliva and artificial saliva at 37 °C, the corrosion resistance of Kera NH®, Kera 501® and PD Casta H® alloys was low compare with that of referance solution, but the effect of temperature and pH on the corrosion resistance of Co-Cr alloy was low compared with that of Ni-Cr alloy. On the basis of the results obtained, our advise would be to recommend to avoid an increase in the oral temperature and reduced the taking of acid food which are likely to lower the oral pH and enhance the corrosion of the Ni-Cr and Co-Cr alloys when the fixed and removable partial dentures treatment.

Authors and Affiliations

Rassam subari, A Bellaouchou, Nadia Merzouk

Keywords

Related Articles

OUR DIAGNOSTIC AND THEARAPEUTIC SURGICAL APPROACHES TO MEDIASTINAL MASSES

The mediastinum is defined as the thoracic space that lies between the two pleural layers. It extends from the thoracic inlet to the superior surface of the diaphragm. It is bordered anteriorly by the internal surface of...

RESTORATION OF POSTERIOR EDENTULOUS SPACES AFTER MAXILLARY MOLAR INTRUSION WITH FIXED APPLIANCES (CASE REPORT)

This case report includes the mini screw supported intrusion of the extruded teeth due to the absence of its antagonist and fixed prosthetic rehabilitation supported with osseointegrated implants. Four mini-screws with...

 A COMPARISON OF Ni-Ti ROTARY AND HAND FILES INSTRUMENTATION IN PRIMARY MOLARS

 The aim of the study was to compare the manual and rotary endodontic instruments focusing on risk of perforation when the whole root canal length is instrumented as well as the time required for preparation in prim...

 ATRETIC PARIETAL CEPHALOCELE

 A posterior paryetal midline subscalp swelling noticed in a 19 month boy, by his family.These nodule had been enlarging slowly since birth. Radiologic imaging revealed that, subscalp lesion is a cyst and there wa...

EVALUATION OF RETRODISKAL TISSUE ASSOCIATED WITH ARTICULAR EMINENCE MORPHOLOGY, EFFUSION STATUS AND DISK DISPLACEMENT IN SYMPTOMATIC PATIENTS

The aim of this study was to evaluate the MRI signal intensity of retrodiskal tissue e and its relationship to articular eminence morphology, joint effusion status and disk displacement in symptomatic patients. Image a...

Download PDF file
  • EP ID EP146754
  • DOI -
  • Views 93
  • Downloads 0

How To Cite

Rassam subari, A Bellaouchou, Nadia Merzouk (2013).  INFLUENCE OF TEMPERATURE AND pH ON CORROSION BEHAVIOR OFNI–CR AND CO-CR DENTAL ALLOYS. Journal of International Dental and Medical Research, 6(1), 9-14. https://europub.co.uk/articles/-A-146754