Performance of an Active DC-Traction Substation with 12-Pulse Parallel Rectifier and Indirect Current Control
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2015, Vol 39, Issue 39
Abstract
The attention in this paper is directed to the transformation of an existing DC-traction substationsequipped with 12-pulse parallel uncontrolled rectifier into an active substation. In this manner, the traction substation gains the capability of redirecting the braking energy to the power supply and the power quality indicators during the traction regime are greatly improved. The practical solution lies in adding a shunt active power filter, accompanied by appropriate circuits of connection on both the DC and AC sides, between the DC-traction line and the primary of the traction transformer via a dedicated recovery transformer. To control the current provided by the shunt active filter in both traction/active filtering and regeneration regimes, the indirect method of handling the supply current has been adopted. The reference supply current during the operation in traction regime is calculated based on instantaneous powers provided by the concepts of the instantaneous reactive power theory. Two compensation strategies have been implemented for this operation mode, i.e. the total compensationof the current harmonics and reactive power and the partial compensation (only the current harmonics). In regeneration mode, the traction rectifier is blocked and the reference supply current is given by the voltage controller. Based on the conceived Matlab/Simulink models of the whole system, the proper operation is confirmed and the good performance of the system during both traction/filtering and regeneration regimes is shown. Indeed, the total harmonic distortion of the supply current is always below the limits and recommendations of the power quality standards and the operation in regeneration mode is allowed.
Authors and Affiliations
Mihaela Popescu, Alexandru Bitoleanu, Alexandra Preda
POWER FACTOR AUTOMATIC COMPENSATION WITHIN 20/6KV ELECTRICAL TRANSFORMATION STATIONS
The addition of the compensation of the power factor is one technical measure to improve the functioning of the electrical installations. Because the loads of the electrical installations show fluctuations in 24 hours an...
Management of Renewable Energy Sources Integrated in a Micro Smart Grid
Future trends in the energy sector are crossing from centralized to distributed electricity production. A national and international organism encourages and informs consumers about the efficient use of energy. Such...
Transversal Shape Optimization of a Brushless DC Motor for Electric Vehicles
The opportunity of this research is to emphasize certain approaches related to the design and modeling of low and medium power permanent magnet brushless DC motors for electric vehicles, which are presently poorly...
COMPARATIVE ACTIVE CURRENT CALCULATION BY p-q AND CPC THEORIES
This paper studies the possibilities of decomposition of the current in three-phase, three-wire systems based on the classic p-q theory proposed by Akagi and further developed and, respectively, on the Czarnecki’s theory...
MODELLING OF ELECTROMECHANICAL CONVERTERS OF TRACTION USED ON ELECTRIC LOCOMOTIVES
The paper begins by presenting basic electrical diagrams of the main types of electric locomotives (with chopper and DC motors or with rectifiers and DC motors or with VVVF and induction motors IM or with self-controlled...