Thermal analysis of baffled shell and tube type EGR cooler for different types of tubes using CFD

Abstract

 Exhaust Gas Recirculation (EGR) technique using EGR cooler reduces the NOx content from the tailpipe emission of Diesel engines. Commercial computational fluid dynamics (CFD) code is used to solve and simulate the flow-fields and temperature distribution of fluids inside the EGR cooler. In this investigation two models (model-a and model-b) of EGR coolers are developed using Pro/Engineer Wildfire 4.0 software. Model-a is a single pass baffled shell and tube heat exchanger with staggered tube arrangement of plain tubes and having conical shaped stationary heads (gas inlet/outlet chamber) [2]. Model-b is having the same tube arrangement and spacing as they were in model-a, but the plain tubes were replaced with internally finned tubes to increase the internal surface area of tubes. The finned tubes are of same outer diameter and same tube material as that of plain tubes. In model-a and model-b, the inlet conditions of both the cooling water and hot gases are the same. These models are analysed with Ansys Fluent 13.0 software. The CFD results show that, by replacing the p

Authors and Affiliations

Ibrahim Hussain Shah1

Keywords

Related Articles

 TEXT-DEPENDENT SPEAKER RECOGNITION SYSTEM IN NOISY ENVIRONMENT USING MFCC

 This paper is about text-dependent speaker recognition system in noisy environment.The goal of this paper is to recognize the speaker using noisy environment or to identify the speaker using noised speech signal....

 Design and Performance analysis of Low power CMOS Op-Amp

 This paper proposes a low power CMOS operational amplifier which operates at 1.8 V power supply. The unique behavior of the MOS transistors in sub-threshold region not only allows a designer to work at low input b...

 [b]Glass Fiber Reinforced Concrete & Its Properties [/b]

Glass fiber reinforced concrete (GFRC) is a recent introduction in the field of civil engineering. So, it has been extensively used in many countries since its introduction two decades ago. This product has advantage of...

 Transformer-less Grid Connected PV Inverter for Single Phase System

 There is a strong trend in the photovoltaic inverter technology to use transformer-less topologies in order to acquire higher efficiencies combining with very low ground leakage current. The DC/AC inverters are us...

SPEED CONTROL OF DC MOTOR A REVIEW

This paper deal with various method of speed control of DC Motor and literature review on speed control of DC motor is presented. DC motors are widely used in industry applications, r obotics and domestic appliances b...

Download PDF file
  • EP ID EP163786
  • DOI -
  • Views 66
  • Downloads 0

How To Cite

Ibrahim Hussain Shah1 (30).  Thermal analysis of baffled shell and tube type EGR cooler for different types of tubes using CFD. International Journal of Engineering Sciences & Research Technology, 3(7), 72-76. https://europub.co.uk/articles/-A-163786