Neutron dose evaluation of Elekta Linac at two energies (10 & 18 MV) by MCNP code and comparison with experimental measurements

Journal Title: JOURNAL OF ADVANCES IN PHYSICS - Year 0, Vol 6, Issue 1

Abstract

Medical linear accelerators, besides the clinically high energy electron and photon beams, produce other secondary particles such as neutrons which escalate the delivered dose. In this study the neutron dose at 10 and 18MV Elekta linac was obtained by using TLD600 and TLD700 as well as Monte Carlo simulation. For neutron dose assessment in 2020 cm2 field, TLDs were calibrated at first. Gamma calibration was performed with 10 and 18 MV linac and neutron calibration was done with 241Am-Be neutron source. For simulation, MCNPX code was used then calculated neutron dose equivalent was compared with measurement data. Neutron dose equivalent at 18 MV was measured by using TLDs on the phantom surface and depths of 1, 2, 3.3, 4, 5 and 6 cm. Neutron dose at depths of less than 3.3cm was zero and maximized at the depth of 4 cm (44.39 mSvGy-1), whereas calculation resulted  in the maximum of 2.32 mSvGy-1 at the same depth. Neutron dose at 10 MV was measured by using TLDs on the phantom surface and depths of 1, 2, 2.5, 3.3, 4 and 5 cm. No photoneutron dose was observed at depths of less than 3.3cm and the maximum was at 4cm equal to 5.44mSvGy-1, however, the calculated data showed the maximum of 0.077mSvGy-1 at the same depth. The comparison between measured photo neutron dose and calculated data along the beam axis in different depths, shows that the measurement data were much more than the calculated data, so it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry in linac central axis due to high photon flux, whereas MCNPX Monte Carlo techniques still remain a valuable tool for photonuclear dose studies.

Authors and Affiliations

Negin Shagholi, Hassan Ali, Mahdi Sadeghi, Arjang Shahvar, Hoda Darestani, Banaee Nooshin, Kheirolah Mohammadi

Keywords

Related Articles

ON THE DISTRIBUTION OF LUMINOUS MATTER IN A FRIEDMANN UNIVERSE

The Friedmann model is considered through stereographic projection of the Friedmann-Roberson-Walker metric for open, flat and closed matter-dominated universe. A relation between redshift and number density of galaxies i...

The effect of etchants on surface of CdTe single crystal

Cadmium telluride crystals (CdTe) have been grown by the sublimation method. The crystal polarity of the CdTe with the zincblend structure has been studied. Two different crystallographic defect and etch pits are reveale...

Effect of the structural changes on the mechanical properties of the sintered films

Polycrystalline films of tin telluride were prepared by sintering technique. The structural investigation of the films with different thicknesses enables to determine lattice parameter, crystallite size and strain existi...

Quantum Double Dot as Quantum Computer Unit

In this work, we have investigated the exchange interaction of two electrons in double lateral quantum dot (which is the base of quantum gate) under effect of external magnetic field, electric field and inter dot distanc...

A New Model for a Non-Linear Electromagnetic Model with Self-Interacting Photons

A new electromagnetism is still expected to be developed. Thus, under such a principle where nature works as a group, an electromagnetism beyond Maxwell is studied. It considers that light metric antecedes electric charg...

Download PDF file
  • EP ID EP653549
  • DOI 10.24297/jap.v6i1.1820
  • Views 68
  • Downloads 0

How To Cite

Negin Shagholi, Hassan Ali, Mahdi Sadeghi, Arjang Shahvar, Hoda Darestani, Banaee Nooshin, Kheirolah Mohammadi (0). Neutron dose evaluation of Elekta Linac at two energies (10 & 18 MV) by MCNP code and comparison with experimental measurements. JOURNAL OF ADVANCES IN PHYSICS, 6(1), 1006-1015. https://europub.co.uk/articles/-A-653549