Neutron dose evaluation of Elekta Linac at two energies (10 & 18 MV) by MCNP code and comparison with experimental measurements

Journal Title: JOURNAL OF ADVANCES IN PHYSICS - Year 0, Vol 6, Issue 1

Abstract

Medical linear accelerators, besides the clinically high energy electron and photon beams, produce other secondary particles such as neutrons which escalate the delivered dose. In this study the neutron dose at 10 and 18MV Elekta linac was obtained by using TLD600 and TLD700 as well as Monte Carlo simulation. For neutron dose assessment in 2020 cm2 field, TLDs were calibrated at first. Gamma calibration was performed with 10 and 18 MV linac and neutron calibration was done with 241Am-Be neutron source. For simulation, MCNPX code was used then calculated neutron dose equivalent was compared with measurement data. Neutron dose equivalent at 18 MV was measured by using TLDs on the phantom surface and depths of 1, 2, 3.3, 4, 5 and 6 cm. Neutron dose at depths of less than 3.3cm was zero and maximized at the depth of 4 cm (44.39 mSvGy-1), whereas calculation resulted  in the maximum of 2.32 mSvGy-1 at the same depth. Neutron dose at 10 MV was measured by using TLDs on the phantom surface and depths of 1, 2, 2.5, 3.3, 4 and 5 cm. No photoneutron dose was observed at depths of less than 3.3cm and the maximum was at 4cm equal to 5.44mSvGy-1, however, the calculated data showed the maximum of 0.077mSvGy-1 at the same depth. The comparison between measured photo neutron dose and calculated data along the beam axis in different depths, shows that the measurement data were much more than the calculated data, so it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry in linac central axis due to high photon flux, whereas MCNPX Monte Carlo techniques still remain a valuable tool for photonuclear dose studies.

Authors and Affiliations

Negin Shagholi, Hassan Ali, Mahdi Sadeghi, Arjang Shahvar, Hoda Darestani, Banaee Nooshin, Kheirolah Mohammadi

Keywords

Related Articles

A Novel Approach To Prevent Damage from Earthquakes and Tsunamis With The Utilization of a Proportional Surface Pyramidal Structure and Modified Underground Two-Part Hexagonal Damping Rubber Bearing Base Isolator

Today, increased tectonic plate activity in the Cascadia Megathrust Subduction Zone, located on the Pacific American Coast, has the potential to cause a massive earthquake with a magnitude upwards of 9.0 on the Richter s...

Low-Inductive Extended Z-Discharge As a Manyrange Source of Radiations

The present paper summarizes the results of studying of nanosecond low-inductive extended discharge as source of electromagnetic radiations and analyzes the works of other research groups that can throw upon additional l...

Analysis of flow of polar and non polar incompressible ferrofluids

In this paper, flow between two parallel plates is analyzed for both polar and non polar ferrofluids. Velocity is obtained without pressure gradient for polar fluid and with pressure gradient for non polar fluid. The sol...

Non-abelian whole gauge symmetry

The wholeness principle is analysed for non-abelian gauge symmetry. This principle states that nature acts through grouping. It says that physical laws should be derived from elds associations. At this work, we consider...

Download PDF file
  • EP ID EP653549
  • DOI 10.24297/jap.v6i1.1820
  • Views 65
  • Downloads 0

How To Cite

Negin Shagholi, Hassan Ali, Mahdi Sadeghi, Arjang Shahvar, Hoda Darestani, Banaee Nooshin, Kheirolah Mohammadi (0). Neutron dose evaluation of Elekta Linac at two energies (10 & 18 MV) by MCNP code and comparison with experimental measurements. JOURNAL OF ADVANCES IN PHYSICS, 6(1), 1006-1015. https://europub.co.uk/articles/-A-653549