New Rapid Detection System for Formaldehyde Mass Concentration

Journal Title: 河南科技大学学报(自然科学版) - Year 2016, Vol 37, Issue 4

Abstract

In order to quickly and accurately obtain the mass concentration of formaldehyde in measured gas,a new rapid detection system for formaldehyde mass concentration was designed based on spectral absorption characteristics. In accordance with the absorption spectrum distribution of formaldehyde,1 730 ~ 1 737 cm(- 1)was selected as band-pass filtering area for the narrowband filter. The effective optical path length was increased with the multiple reentry absorb gas chamber,and the detection accuracy of formaldehyde mass concentration was improved. The air in newly renovated house,furniture stores and closed office buildings were tested,and the experimental data were compared with the TT-PN-50 P formaldehyde detector. Experimental results show when the formaldehyde mass concentration is higher than 100 μg / m3,the test results are similar with the values from TT-PN-50 P formaldehyde detector,and the average error is less than 2%. When the formaldehyde mass concentration is less than 100 μg / m3,the test data are smaller than the values from TT-PN-50 P formaldehyde detector,and the average error increases,but it still meets the test requirements.

Authors and Affiliations

Yun LIU, Bo WANG, Zhichao LIU

Keywords

Related Articles

Weighted Nitsche Discontinuous Galerkin Finite Element Method of Elasticity Problems

By combining the traditional discontinuous Galerkin finite element method with the weighted Nistche method, a weighted Nistche discontinuous Galerkin finite element method was developed for elasticity problems. In this m...

Block-by-block Method of Impulsive Differential Equations

To solve the initial-value problem of impulsive differential equation,the impulsive differential equation was transformed to an equivalent integral equation. Then a higher order numerical scheme for the equivalent integr...

Synthesization of o-amino Benzonic Acid Modified β-cyclodextrin and Palladium Catalyzed Heck Coupling Reaction in Aqueous Media

Taking o-amino benzonic acid andβ-CD as raw materials, mono- (6-o-amino benzonic acid-6-deoxy) -β-CD was synthesized and characterized by1H NMR and13C NMR.Heck coupling reaction was proceeded with high efficiency in aque...

Verification of Type A Evaluation Methods of Uncertainty Based on Monte Carlo Method

To solve the reliability problem of uncertainty evaluation method based on objective probability, by using the advantages of Monte Carlo method (MCM) suitable for computer simulation, the accuracy of three kinds of type...

Research on Leakage Induced Energy Buffer Feedback Unit Based on Flyback Converter

The resistance of traditional resistor-capacitor leakage absorption circuit of high-frequency transformer was used to dissipate leakage energy, which leads to the low convertor's efficiency. In this paper, an energy buff...

Download PDF file
  • EP ID EP477183
  • DOI 10.15926/j.cnki.issn1672-6871.2016.04.021
  • Views 86
  • Downloads 0

How To Cite

Yun LIU, Bo WANG, Zhichao LIU (2016). New Rapid Detection System for Formaldehyde Mass Concentration. 河南科技大学学报(自然科学版), 37(4), 101-104. https://europub.co.uk/articles/-A-477183