NOISE RISK ASSESSMENT AT AIR SEPARATION PLANT PT. X SURABAYA (NITROGEN, OXYGEN, AND ARGON PLANT)

Journal Title: Journal of Vocational Health Studies - Year 2017, Vol 1, Issue 2

Abstract

Background : Noise was one of the dangerous factors at a workplace which causes various effects on workers. Purpose : The purpose of this research was to described the activity stages, identified the noise danger, and assessed the risk and its level at Air Separation Plant of PT. X. Methods : This research was a descriptive research with a cross sectional approach. The object of the research was the noise danger potential and the noise risk level assessment at Air Separation Plant of PT. X. Results : The result of this research showed that there were 12 identified noise danger points. These results consisted of 5 (42 %) noise risks with low category, 2 (16 %) with middle category, and another 5 (42 %) with high category. The highest noise intensity measurement result was found on Recycle Nitrogen Compressor (RNC) machine, which was 116,5 dBA. Conclusion : Based on this data, it can be concluded that there were 12 identified noise danger points and the highest noise intensity measurement result was found on Recycle Nitrogen Compressor (RNC) machine, which was 116,5 dBA. It is suggested for the related company to execute controls mostly in diminishing the noise sources.

Authors and Affiliations

Hanif Rizqi Dinari, Tofan Agung Eka Prasetya, Erwin Dyah Nawawinetu, Abdul Rohim Tualeka

Keywords

Related Articles

THE CORRELATION OF CHEMICAL EXPOSURE AND PERSONAL HYGIENE WITH IRRITANT CONTACT DERMATITIS AMONG WORKERS IN THE PRODUCTION WORKER

Background: The production process at PT. X using oxalic acid as a mixture of Gum Rosin and Turpentine. Oxalic acid is corrosive and toxic and readily oxidized by water and oxygen that can cause irritation, rashes, burns...

STUDY OF SOIL-TRANSMITTED HELMINTHIASIS PREVALENCE IN SCHOOL CHILDREN IN SURABAYA

Background : Soil-Transmitted Helminths infection usually occurs due to poor sanitation in the densely populated area with bad sanitation. It is transmitted by egg present in human feces then contaminate soil. Helminths...

ANALYSIS OF MYCOPLASMA GALLISEPTICUM INFECTION FACTORS IN COMMERCIAL LAYER CHICKEN FARM USING ANALYTICAL HIERARCHY PROCESS

Background : Mycoplasma galliseptium (MG) is a pathogenic microbial often found in poultry farm industry. In Indonesia there are rarely data of MG research. There are some factors increased the risk of MG infection. Purp...

MONOLIER (MONOPOLI 5R): INNOVATION OF MONOPOLY GAMES AS 5R LEARNING MEDIA FOR EARLY EDUCATION

Background: The understanding of 5R (Ringkas, Rapi, Resik, Rawat, and Rajin) is still low among the people. This is due to the lack of early education on the 5R concept. MONOLIER (Monopoly 5R) is an inovation of learning...

MAKING SINGLE COMPLETE DENTURES FOR THE MATERIAL WITH TUBER MAXILLA CASE LARGE

Background: single complete denture is complete denture where its antagonist there tooth original good in part or else entirely. Besides that on case this there bulge tuber maxilla more big of the normal size of course o...

Download PDF file
  • EP ID EP594199
  • DOI 10.20473/jvhs.V1.I2.2017.70-74
  • Views 329
  • Downloads 0

How To Cite

Hanif Rizqi Dinari, Tofan Agung Eka Prasetya, Erwin Dyah Nawawinetu, Abdul Rohim Tualeka (2017). NOISE RISK ASSESSMENT AT AIR SEPARATION PLANT PT. X SURABAYA (NITROGEN, OXYGEN, AND ARGON PLANT). Journal of Vocational Health Studies, 1(2), 70-74. https://europub.co.uk/articles/-A-594199