Numerical Analysis of Smoke Temperature Characteristics below the Fire Ceiling in Main Transformer Room of Urban Rail Transit Substation

Journal Title: Urban Mass Transit - Year 2024, Vol 27, Issue 7

Abstract

Objective With the increasing power supply load required by metro, the operation of oil-immersed equipment such as wet-type transformers under overload conditions is extremely prone to fire, posing a threat to the safety of ceiling structure. To avoid or reduce the possibility of transformer fires, it is necessary to investigate the smoke movement patterns and the variation characteristics of ceiling temperature in main transformer room during fire. Method Taking the 110 kV Qichuan Substation of Jinan Rail Transit Line 3 as example, through theoretical analysis and numerical simulation, considering the comprehensive effects of ventilation conditions, fire heat release rate, and fire source height, the temperature characteristics of smoke below the ceiling in main transformer room during fire are investigated. Result & Conclusion When mechanical ventilation is activated, the organization of indoor airflow will affect the distribution of smoke temperature below the ceiling. Wind replenishment causes the fire plume to deflect, leading to the maximum temperature rise point shifting towards exhaust vents, with the maximum temperature rise slightly lower than when mechanical ventilation is closed. The dimensionless maximum ceiling temperature rise can be divided into two regions: when the flame does not impinge on the ceiling, it exhibits a linear relationship between the dimensionless maximum temperature rise and the ratio of Q2/5 and (hef-h0) (where Q is the fire heat release rate, hef is the distance from fire source surface to the ceiling, h0 is the virtual point source height); when the fire flame impinges on the ceiling, the dimensionless maximum temperature rise is a constant, and a prediction model for the dimensionless maximum temperature rise of the ceiling is proposed. Based on simulation data, prediction models for temperature decrease of ceiling jets driven by weak and strong fire plumes are proposed.

Authors and Affiliations

Lu GAN, Hao WANG, Haoran YANG, Lin XU

Keywords

Related Articles

Influence Law of PBA Method New Station Closely Undercrossing Existing Station on Its Structural Deformation

Objective A new station constructed with PBA method closely undercrossing existing station will influence the deformation of the latter′s structure. The influence law needs to be studied. Method Based on the project of P...

Fire Smoke Control and Personnel Safety Evacuation under Dual-train Tracking Mode in Urban Rail Transit Ultra-long Tunnel

Objective In urban rail transit, train departure intervals are generally short, leading to situations where two trains travel in the same direction within ultra-long tunnels. In the event of a fire, this scenario can res...

Urban Rail Transit Vehicle Light-weighting and Energy-saving Technologies

[Objective] The increasing use of fully automated driving and high-redundancy technologies in urban rail transit vehicles (hereinafter referred to as ′metro′) leads to the increase of on-board device amount to varying de...

Assessment and Optimization Strategies of Tram Station Environment Based on Park City Scene Creation

Objective In the development context of ecological construction and new urbanization for park cities in the current new-era, the main theme is to explore the planning direction and influencing factors of urban new scene...

Analysis and Improvement of Pantograph Carbon Strip Abnormal Wear on Luoyang Metro Line 1

Objective During inspection, problems like the bad pantograph and catenary relation, pantograph-catenary arcing on the main line, burning points and serious wear on the pantograph carbon strip are detected since the tria...

Download PDF file
  • EP ID EP742620
  • DOI 10.16037/j.1007-869x.2024.07.036
  • Views 15
  • Downloads 0

How To Cite

Lu GAN, Hao WANG, Haoran YANG, Lin XU (2024). Numerical Analysis of Smoke Temperature Characteristics below the Fire Ceiling in Main Transformer Room of Urban Rail Transit Substation. Urban Mass Transit, 27(7), -. https://europub.co.uk/articles/-A-742620