On-site diagnostics of the mechanical ventilation in office buildings
Journal Title: Architecture Civil Engineering Environment - Year 2017, Vol 0, Issue 0
Abstract
The methodology for inspecting the ventilation system and on-site measurements for office buildings has been proposed under the project “Development of thermal diagnostics of buildings”. The inspections of the ventilation system in two office buildings were conducted. The design documentation was compared with the existing state of the installations. The measurements of the air flow volume, of the temperature of ventilation air and of the volume flow of the heating medium and its temperature were performed. The measurements allowed to determine the power of the heater referring to the heating medium and to the air. On the basis of the inspection and measurements performed, the technical condition of the ventilation system was determined and its utilization in each of the buildings.
Authors and Affiliations
M. Blaszczok
Architectural features of military architectural structures in Poznań
This paper aims to present architectural and educational features of historic military architectural structures in Poznań. The issues treated herein include the preservation of forts today and the resulting opportunities...
Economic aspects of sustainable sanitation in rural settlements
This paper presents discussion of the problem of rural sanitation economic sustainability, affecting the overall investment agreement with the principles of sustainable development. In our opinion, economic aspects of su...
Flow capacity analysis for MPL Katowice Pyrzowice terminals with the indication of zones requiring architectonic changes
In order to improve the quality of passenger service at an airport terminal it is necessary to continuously monitor the level of the services rendered. Devising a strategy for the process of modernization or extension of...
On-site diagnostics of the mechanical ventilation in office buildings
The methodology for inspecting the ventilation system and on-site measurements for office buildings has been proposed under the project “Development of thermal diagnostics of buildings”. The inspections of the ventilatio...
Optimization of window size design for detached house using TRNSYS simulations and genetic algorithm
Heat gains from the sun affect the heat balance of building by reducing the energy demand at certain periods of the year and increasing it at others. Windows, especially the type of glazing, are a determining factor in t...