On the Equivalent Sources and Geometric Factor Calculation for a Circular Detection Case

Abstract

In all absolute measurements of the intensity of the radioactive materials and calibration of the detectors, it is essential the knowledge of the geometric efficiency. This work describes how to obtain the sources with different geometries and equal geometric efficiency (equivalent sources for geometric factor), corresponding to a linear, circumferential and circular homogeneous sources parallel to a circular detector. It is estimated the geometric factor of them by the Monte Carlo method. The results are compared with the published in the literature, thus confirming the validity of this method.

Authors and Affiliations

A. Tony Viloria, Luis Montiel, Laszlo Sajo-Bohus, Daniel Palacios

Keywords

Related Articles

Analysis of the Energy Deposit in the Air by Radiation of Alpha Particles Emitted by the Water of a Spring Through the Geant4 Software.

This work presents the development of an analysis of the potential radiological risk generated by alpha particles emitted by radon-222, content in a spring water, for the population that usually swims in the place and fo...

Multiphoton Ionization of Uracil at 355 nm

We present the experimental results from ionization and dissociation by multiphoton absorption (MPI) of uracil and a mixture of uracil with Ar using a Reflectron time of flight spectrometer along with radiation from 355...

Probable Projectile-Target Combinations for the Synthesis of Super Heavy Nucleus 286112

The fusion cross sections for the reactions of all the projectile-target combinations found in the cold valleys of 286112 have been studied using scattering potential as the sum of Coulomb and proximity...

Beam Behaviour and Magnetic Field of K500 SCC

The extraction of the beam from the k500 Superconducting Cyclotron in kolkata is posing a great challenge. After getting the internal beam, lots of effort were made to extract the beam and thereafter various experiments...

Alignment Studies for Tungsten Near L3 Sub-Shell Threshold Via Theoretical, Experimental and Empirical Methods

Alignment studies are made for tungsten near L3 sub-shell threshold using theoretical, experimental and empirical approaches. Experimentally to measure alignment parameter, the angular distribution of L x-rays of tungste...