On the relationship between J-integral and CTOD for CT and SENB specimens

Journal Title: Frattura ed Integrità Strutturale - Year 2008, Vol 2, Issue 6

Abstract

In this investigation the relationship between J-integral and CTOD is studied considering a Compact Tensile (CT) and Single edge notched bend (SENB) specimens using finite element analysis. The magnitude of CTOD is estimated by 90o-intercept method and also by plastic hinge model. The results indicate that there exists a discrepancy in estimation of CTOD by 90o-intercept method and by plastic hinge model. The CTOD values obtained by both the methods are found to be linearly proportional to J-integral. The linear proportionality constant dn between CTOD and J is found to strongly depend on the method of estimation of CTOD, specimen geometry and a/W ratio of the specimens.

Authors and Affiliations

S. K. Kudari, K. G. Kodancha

Keywords

Related Articles

 Evaluation and visualization of multiaxial stress and strain states under non-proportional loading

 This paper presents a simple method of determining stresses and strains and a severity of loading history under non-proportional loadings with defining the rotation angles of the maximum principal stress and strai...

 Multi-purpose fatigue sensor. Part 1. Uniaxial and multiaxial fatigue

  The paper describes the key principles and results of preliminary experiments aimed at the development of new technique for the fatigue life prediction under conditions of biaxial cyclic tension. The foundations o...

 Development of an engineering methodology for non-linear fracture analysis of impact-damaged pressurized spacecraft structures

 Motivated by the dramatic worsening and uncertainty of orbital debris situation, the present paper is focused on the structural integrity of the spacecraft pressurized modules/pressure vessels. The objective is to...

 On fatigue behavior of two spring steels. Part I: Wöhler curves and fractured surfaces

 Symmetric fatigue in two spring steels is investigated in three groups of specimens. One of the groups (Steel EN10270-1SH/ DIN 17223C – C 0.82%, Mn 0.76%, Si 0.26%) has experienced rotating-bending fatigue in...

 Inter-laminar shear stress in hybrid CFRP/austenitic steel

 Bolted joints are the most common solution for joining composite components in aerospace structures. Critical structures such as wing to fuselage joints, or flight control surface fittings use bolted joining tech...

Download PDF file
  • EP ID EP92222
  • DOI 10.3221/IGF-ESIS.06.01
  • Views 67
  • Downloads 0

How To Cite

S. K. Kudari, K. G. Kodancha (2008). On the relationship between J-integral and CTOD for CT and SENB specimens. Frattura ed Integrità Strutturale, 2(6), 3-10. https://europub.co.uk/articles/-A-92222