Open reduction internal fixation with plating versus external fixator in distal end radius fractures: A comparative study

Journal Title: National Journal of Clinical Orthopaedics - Year 2018, Vol 2, Issue 4

Abstract

Introduction: Low energy falls leading to stable variety of fracture patterns are seen most commonly, but young patients tend to have a high-energy mechanism of injury. Nonsurgical management remains main line of management; however, there are a variety of treatment options available for fractures too unstable for non-operative management. These include external fixation, percutaneous pinning, and internal fixation. The primary goal of treatment of these fractures is restoration of wrist function. Good functional outcome requires restoration of the disrupted radial anatomy, maintenance of accurate and stable reduction. There is no standard treatment algorithm for these fractures as most of the textbooks refer it as author’s experience. Various studies have shown excellent result with volar plating and early functional recovery. Assessment of the functional outcome between the volar platting and the external fixation with or without pinning in displaced distal radius fractures was the purpose our study. We hypothesized that there would be significantly fewer complications and improved clinical results in the volar plating group when compared to the external fixation group. Aim: To assess the functional outcome between the Volar platting and the external fixation with or without pinning in displaced distal radius fractures. Materials and Methods: This is an observational type of retrospective study where 40 patients were included in the study and among them 20 with external fixator/k wire and 20 with distal radius plating on whom the study conducted. Assessment of the fracture was based on AO classification. Adult Patients above age of 18 years with AO type B and C included in study. Patients with open/compound, pathological fractures excluded from study. Patients followed up at 6 weeks, 3 months, 6 months, 9 months and 12 months. At the 12 month follow-up final assessment was done for fracture union and patients were assessed for pain, wrist range of motion (ROM), grip strength and activity and scored according to the Modified Green O’Brien Scoring System. Results and Discussion: In present study, we got excellent functional results according to the G and O’Brein system in 11(55%) of patients treated with ORIF with plating group as compared to 4(20%) patients in the External fixation group. There was a significant difference in the mean value of the functional result in the Plating group (76.5) as compared to external fixator group (89.5).We evaluated our results and compared them with those obtained by various other studies utilising different modalities of treatment. Conclusion: Both ORIF plating and external fixation are good treatment choices for distal end radius fractures. ORIF PLATING provides better functional outcome as assessed by Green and O'Brien score as compared to external fixation.

Authors and Affiliations

Dr. Rameez Musa, Dr. Neel Bhavsar, Dr. Darshan Shah, Dr. Prarthan Amin, Dr. Jeet Gandhi, Dr. Shobhit Taneja

Keywords

Related Articles

Epidemiology of injuries in school: Analysis of 3285 medical entries in a suburban school

Background: Injuries in school are a common phenomenon. However, we do not yet know the incidence of these injuries. We, therefore, examined the medical record of a busy suburban school to understand the pattern of injur...

Functional outcome of open surgical repair of full thickness rotator cuff tears using the double row suture anchorage technique

Introduction: The arthroscopic method offers several advantages, including smaller incisions, access to the gleno-humeral joint for the inspection and treatment of intra-articular lesions, no need for detachment of the d...

Results of uncemented THR in Indian patients in Indian conditions

Introduction: The hip joint is the most important joint of the body as it enables a person to assume various postures. Diseases of this joint are always alarming because if untreated, produces serious disability, for thi...

Open reduction internal fixation with plating versus external fixator in distal end radius fractures: A comparative study

Introduction: Low energy falls leading to stable variety of fracture patterns are seen most commonly, but young patients tend to have a high-energy mechanism of injury. Nonsurgical management remains main line of managem...

To assess how the surgical plan changes after introducing CT scans

Background: This study aims to assess how surgical plans changes after introducing CT scans, which is conducted at Amaltas Institute of Medical Sciences, Dewas, (M.P.) The patient‟s clinical history and examination findi...

Download PDF file
  • EP ID EP507051
  • DOI -
  • Views 73
  • Downloads 0

How To Cite

Dr. Rameez Musa, Dr. Neel Bhavsar, Dr. Darshan Shah, Dr. Prarthan Amin, Dr. Jeet Gandhi, Dr. Shobhit Taneja (2018). Open reduction internal fixation with plating versus external fixator in distal end radius fractures: A comparative study. National Journal of Clinical Orthopaedics, 2(4), 158-164. https://europub.co.uk/articles/-A-507051