OPERATION OF A MUNICIPAL COMBINED HEAT AND POWER (CHP) IN THE BLACKOUT CONDITIONS EXEMPLIFIED BY A SELECTED HIGH-POWER OBJECT
Journal Title: Proceedings of Electrotechnical Institute Prace Instytutu Elektrotechniki - Year 2012, Vol 59, Issue 260
Abstract
The hazard of blackout occurrence in the Polish national power system keeps growing. In the blackout conditions one of the protection methods is to separate a balanced load island as a power source for a municipal CHP. The paper discusses the significance of a municipal CHP as a guarantee of local and global power safety. It also includes an analysis of hazardous conditions for the CHP technical equipment when voltage collapse occurs in the system as well as a discussion of technical aspects concerning adjustment of the equipment and auxiliaries to islanding conditions or auxiliary services.
Authors and Affiliations
Mariusz SZYMANEK
NOWE ABSORBERY ORGANICZNE DO MODYFIKACJI WYROBÓW Z WŁÓKIEN CELULOZOWYCH PRZEZNACZONYCH NA ŚRODKI OCHRONY INDYWIDUALNEJ PRZED PROMIENIOWANIEM NADFIOLETOWYM
Najważniejszym elementem ochrony skóry przed szkodliwym wpływem promieniowania ultrafioletowego naturalnego i emitowanego przez źródła sztuczne jest odzież wykonana z materiałów włókienniczych o odpowiednich właściwościa...
THE LINEARIZATION OF DYNAMICS OF THE WIENER-HAMMMERSTEIN MODEL AND SIMPLIFICATION OF NONLINEAR MODELS OF MEASURING SYSTEMS FOR SLOWLY-ALTERING SIGNALS
The simplified models of linear systems created by expanding of the integrand of convolution integral in Taylor's series are relatively accurate for slowly-altering, smooth input signals. Using this models one can do suc...
MODELING AND SIMULATIONS OF A NON-LINEAR COIL
Solving rigid differential equations systems should be performed with the application of implicit or semi-explicit methods. As proven in the example given in this paper – the implicit RADAU IIA methods can be successfull...
BUBBLE EFFECT W UKŁADZIE IZOLACYJNYM PAPIER-ESTER SYNTETYCZNY
Zjawisko bąbelkowania (bubble effect, BE) występuje w transformatorach o układzie izolacyjnym papier-olej mineralny. Polega ono na gwałtownym uwalnianiu wody z zawilgoconej izolacji celulozowej po przekroczeniu krytyczne...
METHOD OF OCCUPATIONAL RISK ASSESSMENT ARISING FROM ARTIFICIAL RADIATAION ACCORDING TO NEW REQUIREMENTS OF LAW
The article indicates the main factors which should be taken into account during the risk assessment related to occupational exposure to artificial optical radiation according to new requirements of law. The scope of el...