Abstract

This paper describes a power plant with electrical/thermal capacity of 750 kW/3.4 MW launched in February 2015 by a private investor in Żory, Poland. The ORC Organic Rankine Cycle technology used there enables turbine operation at a lower temperature of the heat medium (thermal oil), so the energy transformation is better suited for biomass combustion. In addition, an innovative solution has been applied, consisting in directing the thermal oil downstream of the turbine to a heat receiver (dryer), instead of a cooling tower, as in traditional solutions. Such a solution significantly improves the CHP plant’s overall efficiency, but it also affects its electric output adjustability. The paper also reports the experience from the plant design and construction phases.

Authors and Affiliations

Grzegorz Błajszczak, Iwona Gaweł

Keywords

Related Articles

Experimental Study of Higher Harmonics Content in Street Lighting System Current

Due to energy efficiency improvement requirements, street lighting system operators tend to reduce the electricity consumed by the lights themselves, and also minimize losses in the system. Smart lighting control systems...

Types of Risks in the Process of Investing in Renewable Electric Energy Sources

The development of renewable power engineering is inevitable. Administrative, financial, political, social, environmental or technical/technological barriers are and must be minimized. They determine the scale of risk bo...

The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid

This paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low...

Reactive Energy Billing in Operator Tariffs in Poland

The paper describes the current method of reactive energy billing in the tariffs of distribution grid operators in Poland. The current solutions are subject to critical assessment. Issues related to the motivation effect...

Laboratory Load Model Based on 150 kVA Power Frequency Con-verter and Simulink Real-Time – Concept, Implementation, Experiments

First section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is pre...

Download PDF file
  • EP ID EP198608
  • DOI 10.12736/issn.2300-3022.2016303
  • Views 36
  • Downloads 0

How To Cite

Grzegorz Błajszczak, Iwona Gaweł (2016). Operational Parameters of Low Power ORC Biomass Plant. Acta Energetica, 28(3), 23-27. https://europub.co.uk/articles/-A-198608