Patient with multiple ICD interventions (RCD code: V‑2A.O)

Journal Title: Journal of Rare Cardiovascular Diseases - Year 2016, Vol 3, Issue 1

Abstract

The authors report a case of a 58-year-old man with coronary artery disease and left ventricular aneurysm following inferior wall infarction, who was implanted with a single chamber cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death. The patient presented with complaints including multiple ICD shocks due to recurrent ventricular tachycardia (VT) resistant to the implemented treatment, decreased quality of life and high level of anxiety associated with multiple hospitalizations. Pharmacological treatment was unsuccessful and led to drug-induced bradycardia. Due to developed pacemaker syndrome the patient underwent ICD upgrade to a dual-chamber device followed by radiofrequency ablation. Despite a number of interventions, VT did not completely disappear. A slight decrease in the number of ICD shocks was observed. After adjustment of the pacing lower rate up to 75 bpm, ventricular arrhythmias were reduced and eventually retreated. In the six months follow-up period no VT was recorded. The authors discuss the current recommendations for VT treatment with the indications for re-ablation or aneurysmectomy. JRCD 2016; 3 (1): 20–23

Authors and Affiliations

Piotr Liszniański

Keywords

Related Articles

3rd Symposium on Rare Cardiovascular Diseases – ESC Amsterdam 2013: Chairperson’s Perspective

The 3rd Satellite Symposiumon Rare Cardiovascular Diseases, which was organized by the Krakow Center for Rare Cardiovascular Diseases, was officially included in the Program of the 2013 ESC Congress and was held in the E...

Pregnancy and congenital complete atrioventricular block: management during pregnancy and the periparturient period

Complete atrioventricular block (AVB) is rare during pregnancy. Congenital atrioventricular block is the most common type of heart block in this group of patients. About one‐third of female patients with complete AVB re...

Senning operation as a palliative therapy for a girl with complex heart defect and Eisenmenger syndrome (RCD code: II‑1A.4d)

Development of irreversible pulmonary hypertension in D-transposition of the great arteries (D-TGA) with ventricular septal defect (VSD) is a well-known phenomenon. Coexistence of left ventricular outflow tract obstructi...

Pulmonary artery pressure matters – how to efficiently improve survival in pulmonary arterial hypertension (RCD code: II‐1A.1)

Pulmonary arterial hypertension is a disease characterized by poor prognosis despite treatment. Even in a modern era of pharmaco- therapy there is a strong need to further improve survival of patients. The current therap...

Heart broken by a mosquito; an unusual case of Takotsubo cardiomyopathy

Pakistan has recently witnessed an epidemic of dengue infection and thereafter, certain various presentations of patients with dengue infection have been reported. The cardiac manifestation of dengue infection is primari...

Download PDF file
  • EP ID EP244136
  • DOI 10.20418/jrcd.vol3no1.261
  • Views 84
  • Downloads 0

How To Cite

Piotr Liszniański (2016). Patient with multiple ICD interventions (RCD code: V‑2A.O). Journal of Rare Cardiovascular Diseases, 3(1), 20-23. https://europub.co.uk/articles/-A-244136