PERFORMANCE OF PRESSURE DIVIDER VALVES IN HYDRAM PUMPS WITH VARIATION OF DIVIDER TUBE LENGTH

Journal Title: Engineering and Technology Journal - Year 8, Vol 8, Issue 10

Abstract

Air is the source of life for humans, plants and animals. One of the efforts to meet water needs is to use a hydram pump. A hydram pump is a pump that works without requiring external power to activate it, but this work is done by utilizing power from a water source. This study aims to determine the effect of using a pressure divider valve on the discharge of waste water and the discharge of water released by the hydram pump. This study used a hydram pump with the specifications of an air tube with a height of 60 cm and a diameter of 3 inches. The height of the waterfall from the pump body is 2 meters and the output height is 4 meters. The height of the air tube on the pressure divider is 20, 25, 30, 35, 40, 45 and 50 cm. The method used in this research is the experimental method. Quantitative data is made in tabular form and displayed graphically. The results showed that the highest wastewater discharge was 0.238 lt/s when using a tube length of 20 cm at an installation height of 2 meters from the pump body and the highest wastewater discharge was 0.232 lt/s when using a tube length of 50 cm. The highest water discharge that can be pumped is 0.0477 lt/s when a tube length of 20 cm is used. While the lowest water discharge pumped was 0.0398 lt/s occurred when using a tube length of 50 cm

Authors and Affiliations

Rudy Sutanto   Sujita .

Keywords

Related Articles

Estimation of Solar Energy Potential Using Sunshine-Based Model for Busa-Baso Kebele, Dirashe Woreda, Ethiopia

The purpose of this study was focused on estimation of solar photovoltaic power systems in Busa Baso, Dirashe Woreda, Ethiopia. Solar photovoltaics are being promoted to replace fuel-based lighting and off-grid electrica...

OPTIMIZATION OF THERMO-FLOW IN A SOLAR FOOD DEHYDRATOR USING COMPUTATIONAL TECHNIQUES

A solar food dehydrator converts solar energy into heat required to remove moisture from food. This study involved development of an optimized design for a solar dehydrator using computational techniques. A computer-aide...

DESIGN AND ANALYSIS OF TWO-STAGE OPERATIONAL TRANSCONDUCTANCE AMPLIFIER WITH COMPENSATION CAPACITOR

For designing of high-performance analog circuits is still a hard task towards reduced supply and increased unity bandwidth. OTA is the basic element with highest power dissipation in many applications. In a handheld dev...

DYNAMIC RESOURCE ALLOCATION ALGORITHM FOR OFDM SYSTEMS (LTESTANDARD)

This paper proposes a resource allocation algorithm for MIMO-OFDM systems (LTE standard). The algorithm is developed for orthogonal frequency division multiple access (OFDMA) system with frequency hopping and adaptive su...

CHEMICAL TREATMENT OF WATER STREAM IN A CONTINUOUS FLOWING PROCESS WITH DOPING TECHNIQUE: CALCIUM HYDROXIDE (CA(OH)2) AS A CASE STUDY

Water from rivers are often characterised with variable compositions influenced by the environment on the path of flow. Treatment with chemicals additives to obtain a level of purification will require repeated test to a...

Download PDF file
  • EP ID EP721842
  • DOI 10.47191/etj/v8i8.17
  • Views 45
  • Downloads 0

How To Cite

Rudy Sutanto   Sujita . (8). PERFORMANCE OF PRESSURE DIVIDER VALVES IN HYDRAM PUMPS WITH VARIATION OF DIVIDER TUBE LENGTH. Engineering and Technology Journal, 8(10), -. https://europub.co.uk/articles/-A-721842