Performance verification and sigma metrics of creatinine assays
Journal Title: International Journal of Clinical Biochemistry and Research - Year 2018, Vol 5, Issue 1
Abstract
Introduction: Creatinine enzymatic method is more accurate but its own higher cost is the main reason why the use of Jaffe assays is still in practice. The verification step is performed because assay procedure confirms to the manufacturer’s claims in the end users’ setup. Desirable specification based on biological variation gives Allowable Total Error (ATE) and Sigma metrics provides summative evaluation of method performance. Objectives: Verification of manufacturer’s precision claims. Calculation of bias, Total Analytical Error (TAE) and sigma metrics. Materials and Methods: Modified Jaffe’s (No deproteinization) and enzymatic creatinine Erba XL liquid pack on Erba EM360 fully auto analyser were used. Intra assay and inter assay imprecision done on 20 replicates each. The estimates of bias uses data from precision experiment. Results & Discussion: The performance of jaffe’s and enzymatic serum creatinine is comparable to manufacturer's stated claimed value and are within desirable specification based on biological variation. The bias calculated in both assays is less than allowable bias. Total Analytical Error (TAE) is less than Allowable Total Error (ATE). Both the methods overall showed ATE ≥ bias + 4 SD. Within-run showed ATE ≥ bias + 5 SD complying Six Sigma concepts. Conclusion: Both Jaffe’s and enzymatic creatinine assays gives good performance and better sigma metrics. This makes enzymatic method a better choice due to inherent advantages such as increased accuracy and less interference if cost is neglected.
Authors and Affiliations
Santosh B. Jagtap, Sanjyoti S. Bandebuche, Mamata V. Hegde
Reduced urinary calcium creatinine ratio - can it be used as an early predictor of hypertensive pregnancies?
Introduction: Pregnancy induced hypertension (PIH) is a multifaceted syndrome with involvement of several important organs and it is associated with endothelial dysfunction. The results from many clinical studies show th...
Relationship between higher Serum ferritin levels, Insulin resistance marker and components of metabolic syndrome in Men and Women in west part of India
Background: There are no effective studies in west part of India on relationship between higher serum ferritin levels in impaired glucose individuals, type 2 diabetes mellitus patients are markers for insulin resistance...
Effect of Chemotherapy on Tumor Marker (Ca 15.3) and Serum in Breast Cancer Patients of Southern Eastern Region of Chhattisgarh; 6 Years Follow up Study
Background: At many centers tumor markers are used to detect disease recurrence and to monitor response to chemotherapy therapy in patients with advanced disease, although the real value of serial observation of marker l...
A study of preanalytical errors in a hospital based clinical biochemistry laboratory and recommendation of required corrective measures
Background & Objective: The errors associated with the total testing process in laboratory, affecting clinical decision making, may occur at the pre-analytical, analytical and post-analytical phase. This study is aimed a...
Study of serum calcidiol level in pregnancy and its association with fetal outcome
Introduction Presently there are no guidelines for routine screening of vitamin D deficiency in antenatal women therefore this study was planned to find the association of maternal vitamin D level with fetal outcomesMate...