PERIODICALLY VARIABLE TWO-TERMINAL IMPEDANCE DESCRIPTION AND MEASURING METHODS

Journal Title: Metrology and Measurement Systems - Year 2007, Vol 14, Issue 3

Abstract

The subject of this paper is the problem how to describe and measure impedance of a linear periodically time-varying (LPTV) two-terminal. If the two-terminal parameters change synchronously to the supply the two-terminal is able to reach a periodical steady state, but supplied with a sinusoidal source produces a non-sinusoidal voltage or current. The LPTV system in the steady state may be described with a circular parametric operator (CPO). Within the discrete time domain, this operator takes the form of a real entries matrix. The circular parametric operator may be transformed into the spectral circular parametric operator (SCPO) using a two-dimensional DFT. This version of description makes it possible to assess quantitatively the LPTV system coercion and response harmonics aliasing. This paper presents two methods of determination of the impedance CPO of the LPTV two-terminal based on current and voltage signal measurements. The first method is designed for operating in the frequency domain, the second one operates in the discrete time domain and takes advantage of a genuine identification algorithm. Some results of computer simulations are presented.

Authors and Affiliations

RADOSŁAW KŁOSIŃSKI

Keywords

Related Articles

ANALYSIS OF THE IRREGULARLY SAMPLED SIGNALS ABOVE THE NYQUIST LIMIT

A new method of spectrum analysis of the nonuniformly sampled data above the Nyquist limit is proposed, which is based on the digital spectral shift to the baseband, optional filtering and the subsequent spectrum analysi...

DYNAMIC MEASUREMENT OF THE CURVE y(x) DEFINED BY PARAMETRIC RELATIONS x(t), y(t) UNDER RANDOM DISTURBANCES

Analog XY-recorders constructed as servomechanisms with sliding motion have been practically out of use for some time. Drawing the curve y(x) defined by parametric relations xz(t), yz(t) under additive, random disturbanc...

ANALYTICAL MODELLING OF KARMAN VORTEX STREET

A new approach to the Karman vortex street modelling is presented. The model is based on observations of the Karman vortex street. The idea of the model is based on fundamental mechanical formulas. According to the model...

NANO-POROUS ALUMINA HUMIDITY SENSORS

In this paper the details of porous alumina humidity sensors fabricated using anodic aluminium oxidation are presented. The main aim of this study is to establish relations between technological process parameters and el...

PROBE CAPACITANCE-DEPENDENT SYSTEMATIC ERROR IN I-V MEASUREMENTS OF NANOWIRES: ANALYSIS AND CORRECTION<br />

We propose a method of eliminating the systematic error due to the capacitance of digital oscilloscope probes in the experimental setup used for tracing current-voltage (I-V) curves of nanowires with quantum point contac...

Download PDF file
  • EP ID EP149814
  • DOI -
  • Views 73
  • Downloads 0

How To Cite

RADOSŁAW KŁOSIŃSKI (2007). PERIODICALLY VARIABLE TWO-TERMINAL IMPEDANCE DESCRIPTION AND MEASURING METHODS. Metrology and Measurement Systems, 14(3), 375-390. https://europub.co.uk/articles/-A-149814