PERIODICALLY VARIABLE TWO-TERMINAL IMPEDANCE DESCRIPTION AND MEASURING METHODS

Journal Title: Metrology and Measurement Systems - Year 2007, Vol 14, Issue 3

Abstract

The subject of this paper is the problem how to describe and measure impedance of a linear periodically time-varying (LPTV) two-terminal. If the two-terminal parameters change synchronously to the supply the two-terminal is able to reach a periodical steady state, but supplied with a sinusoidal source produces a non-sinusoidal voltage or current. The LPTV system in the steady state may be described with a circular parametric operator (CPO). Within the discrete time domain, this operator takes the form of a real entries matrix. The circular parametric operator may be transformed into the spectral circular parametric operator (SCPO) using a two-dimensional DFT. This version of description makes it possible to assess quantitatively the LPTV system coercion and response harmonics aliasing. This paper presents two methods of determination of the impedance CPO of the LPTV two-terminal based on current and voltage signal measurements. The first method is designed for operating in the frequency domain, the second one operates in the discrete time domain and takes advantage of a genuine identification algorithm. Some results of computer simulations are presented.

Authors and Affiliations

RADOSŁAW KŁOSIŃSKI

Keywords

Related Articles

ADVANCES AND GENERIC PROBLEMS IN INSTRUMENT DESIGN METHODOLOGY

The paper is based on a long-term programme of research on mathematical modelling and design of instruments and instrument elements in the Measurement and Instrumentation Centre of City University, London. It considers t...

THE EVOLVING SCIENCE OF MEASUREMENT

This special issue of Metrology and Measurement Systems contains an updated and extended version of selected papers published in the proceedings of the XVIII IMEKO World Congress, held in September 2006 in Rio de Janeiro...

THE INFLUENCE OF INACCURACY OF CALCULATING ALGORITHMS USED IN THE CMMS ON MEASUREMENT RESULTS -FINAL REPORT<br />

The author has devised a test for evaluating the accuracy of calculation algorithms and used it to establish the accuracy of the software of fourteen CMMs offered by world top manufacturers. Using a minimum number of mea...

OPTICAL INSPECTION OF FORMED SHEET METAL PARTS APPLYING FRINGE PROJECTION SYSTEMS AND VIRTUAL FIXATION

Modern forming technology allows the production of highly sophisticated free form sheet metal components, which are subject to a reversible geometrical deformation caused by residual stress, gravity or variations of the...

CHARGE-DENSITY-WAV FEATURES IN TUNNEL SPECTRA OF HIGH-T SUPERCONDUCTORS

Tunnel conductance G(V) was calculated for junctions between a normal metal and a spatially inhomogeneous superconductor with a dielectric gap on the nested sections of the Fermi surface or between two such superconducto...

Download PDF file
  • EP ID EP149814
  • DOI -
  • Views 54
  • Downloads 0

How To Cite

RADOSŁAW KŁOSIŃSKI (2007). PERIODICALLY VARIABLE TWO-TERMINAL IMPEDANCE DESCRIPTION AND MEASURING METHODS. Metrology and Measurement Systems, 14(3), 375-390. https://europub.co.uk/articles/-A-149814