THE POROACCESSIBILITY PARAMETERS FOR THREE-DIMENSIONAL CHARACTERIZATION OF ORTHOPAEDIC IMPLANTS POROUS COATINGS<br />

Journal Title: Metrology and Measurement Systems - Year 2008, Vol 15, Issue 2

Abstract

The ability of formation of the proper bone-porous implant fixation depends, among others, on the structural-osteoinductive properties of the porous coating covering the orthopaedic implant surface. These properties, describing the poroaccessibility of porous biomaterial, are one of co-factors conditioning the promotion of bone tissue ingrowth into pore space of implant porous coating. So far the structural-osteoinductive properties of implants porous coatings are described by the traditional two-dimensional roughness parameters obtained with contact or non-contact roughness profile measurement (mostly standard surface roughness amplitude parameters e.g.: Ra, Rq, Rmax) or with the average pore size, which is, in the authors opinion, inadequate and unsatisfactory for porous coating characterization in respect of its poroaccessibility. The lack of proper directives on porous structure characterization of titanium and hydroxyapatite coatings on orthopaedic implants is the reason to work them out. In connection with the development of methods for surface texture analysis in three dimensions, the authors have perceived new possibilities for porous coatings microstructure analysis and on this base a set of parameters of poroaccessibility of implant porous coating for bone tissue ingrowth has been proposed: the effective volumetric porosity ΦVef , the index of the porous coating space capacity VPM, the representative surface porosity ΦSrep, the representative pore size pSrep, the representative angle of the poroaccessibility Ωrep and the bone-implant interface adhesive surface enlargement index Ψ. With this set of parameters one can characterize the structural-osteoinductive properties of porous biomaterial. In this paper a new set of poroaccessibility parameters of implant porous coatings and a method of calculation of these parameters on the basis of three-dimensional roughness measurements are presented.

Authors and Affiliations

R. UKLEJEWSKI, M. WINIECK, J. MIELNICZUK, P. ROGALA, A. AUGUŚCIŃSKI

Keywords

Related Articles

INTERRUPTER VALVE KINEMATICS IN THE ISSUES OF PARAMETER ESTIMATION OF THE RESPIRATORY SYSTEM MODEL

The latest papers have been suggesting that the dynamics of transient state should be taken into account as the phenomena which occur in a respiratory system are interpreted (quantitatively and qualitatively). The influe...

ADVANCED NANOMETROLOGY TECHNIQUES OF CARBON NANOTUBES CHARACTERIZATION

It has become evident that carbon nanotubes (CNTs) possess exceptionally high physical, mechanical, electrical, and structural properties that made them attractive for researchers to investigate. In this paper, CNTs synt...

SELF-CONFIGURING MEASUREMENT NETWORKS

This discussion paper presents issues in the design of self-configuring networked measurement systems. Key requisites are summarized at first. Then, architectural features will be analyzed in order to let a designer be a...

NEW INSTRUMENTS TO MEASURE PARAMETERS OF INFRA-LOW FREQUENCY VOLTAGE SIGNALS<br />

The paper presents the design, the principles of operation and the technical specification of two types of infra-low frequency voltage instruments: the integrating converter instrument and the microprocessor instrument....

ACCURACY ANALYSIS OF WIM SYSTEMS CALIBRATED USING PRE-WEIGHED VEHICLES METHOD

Accuracy of WIM (Weigh-In-Motion) systems depends on several factors, of particular importance is the calibration procedure. Parameters of the calibration process have essential influence on accuracy of weighing results....

Download PDF file
  • EP ID EP134140
  • DOI -
  • Views 63
  • Downloads 0

How To Cite

R. UKLEJEWSKI, M. WINIECK, J. MIELNICZUK, P. ROGALA, A. AUGUŚCIŃSKI (2008). THE POROACCESSIBILITY PARAMETERS FOR THREE-DIMENSIONAL CHARACTERIZATION OF ORTHOPAEDIC IMPLANTS POROUS COATINGS<br /> . Metrology and Measurement Systems, 15(2), 215-226. https://europub.co.uk/articles/-A-134140