INTERRUPTER VALVE KINEMATICS IN THE ISSUES OF PARAMETER ESTIMATION OF THE RESPIRATORY SYSTEM MODEL

Journal Title: Metrology and Measurement Systems - Year 2007, Vol 14, Issue 3

Abstract

The latest papers have been suggesting that the dynamics of transient state should be taken into account as the phenomena which occur in a respiratory system are interpreted (quantitatively and qualitatively). The influence of geometry and closure valve characteristic on the precision of obtained estimators of its parameters has been analyzed in the paper for the chosen model structure of the system. Results of simulation studies show that minimalization of mean-squared uncertainty dMSE of the model elements estimation is obtained as valve closing (opening) time is shortened and its complete closure time is extended so that a linear increase in pressure Pao is included.

Authors and Affiliations

IRENEUSZ JABŁOŃSKI, ANUSZ MROCZKA

Keywords

Related Articles

NEW INSTRUMENTS TO MEASURE PARAMETERS OF INFRA-LOW FREQUENCY VOLTAGE SIGNALS<br />

The paper presents the design, the principles of operation and the technical specification of two types of infra-low frequency voltage instruments: the integrating converter instrument and the microprocessor instrument....

DYNAMIC MODELS OF ION-SELECTIVE ELECTRODES WITH THEIR ELECTRONIC INTERFACE

Dynamic models of an ion-selective electrode are analysed in this article taking into account the independence of values of its dynamic parameters from the value and direction of activity change. Unfortunately, a complic...

TENTH ANNIVERSARY OF CHAIR OF ELECTRONIC AND PHOTONIC<br /> METROLOGY WROCŁAW UNIVERSITY OF TECHNOLOGY

This year the Chair of Electronic and PhotonicMetrology from Wrocław University of Technology celebrates its 10th anniversary. The Chair was established by the Senate of Wrocław University of Technology on January 27, 19...

FORMAL DEFINITION AND PROPERTIES OF FEB-BASED ENOB OF INTELLIGENT CYCLIC ADC

The paper presents a new approach to the measurement of effective resolution (effective number of bits - ENOB) of the cyclic A/D converters (CADCs). The core idea of the approach is a direct measurement of ENOB using, as...

ANALOG DOT RECORDING AS AN EXEMPLARY PROBLEM IN THE AREA OF DYNAMIC MEASUREMENTS<br />

Analog recorders as typical measuring instruments disappear from contemporary equipment due to progress of digital measurements and common possibilities of measurement data storage in a computer memory. However, recorder...