Possible Interactions Between Stent and Electromagnetic Field
Journal Title: Science, Technology and Innovation - Year 2018, Vol 3, Issue 2
Abstract
Over the past years, an increase in the amount of the electromagnetic sources could be observed. Model presented in this article is limited to the impact of low frequency fields generated by the e.g. electrical power lines or magnetic coils in a bone fractures therapy. Particularly, the effect of the magnetic component of the electromagnetic field on stents will be evaluated. The conductivity of human tissues will be investigated. Yielded results will be used to simplify complicated, three-dimensional problem of the current distribution in stent branches, to one-dimensional one. The merits of the paper is proposing, implementing and using for analysis a numerical model of the stent in magnetic field. The impact of frequency and positioning of stent in the magnetic field will be investigated and current distributions found.<br/><br/>
Authors and Affiliations
Cristian Barz, Marek Petters, Adam Dorsz, Przemysław Syrek
Thermal and long period stability of series of V(V), V(IV) and V(III) complex with Schiff base ligands in solid state
The synthesis and physicochemical properties of three new complexes of vanadium at +5, +4 and +3 oxidation state are described and discussed. The octahedral surrounding of vanadium for V(III) complexes of [V(L1)(HL1)] ge...
Synthesis, structure and properties of V(V) monooxido complex with ONO tridentate Schiff base
The oxidovanadium(V) Schiff base complex of formula [VO(L)(EtO)(EtOH)] (where H2L = Schiff base ligand derived from 5-methoxysalicylaldehyde and phenylacetic hydrazide) was synthesized and described. Complex crystalizes...
Synthesis, structure and properties of V(IV) complex with N’-[(E)-(2,3-dihydroxyphenyl)metylidene]-2-phenylacetohydrazide
The synthesis and physicochemical properties of new vanadium(IV) complex of formula [VO(L)(phen)] is described. The L denotes ONO tridentate Schiff base derived from 2,3-dihydroxybenzaldehyde and phenylacetic hydrazide,...
Possible Interactions Between Stent and Electromagnetic Field
Over the past years, an increase in the amount of the electromagnetic sources could be observed. Model presented in this article is limited to the impact of low frequency fields generated by the e.g. electrical power lin...
Optimization of anethole determination using differential pulse voltammetry on glassy carbon electrode, boron doped diamond electrode and carbon paste electrode
Voltammetry is the general term for all techniques in which the current is measured as a function of electrode potential. The voltammetric techniques can be applied for the quantitative analysis of inorganic and organic...