Preliminary Results of Quality Control for Linear Accelerator at Oncology Center in Nouakchott

Journal Title: Journal of Advances in Medicine and Medical Research - Year 2017, Vol 22, Issue 2

Abstract

The National Center of Oncology in Nouakchott is equipped with a linear accelerator which provides two energies in photon regime 6 MV and 18 MV. The basic dosimetric data required for quality of operation, in the clinical routine of the accelerator for photon beams are percentage depth dose (PDD) curves and beam profile (BP) curves. The aim of this work is to measure the percentage depth dose (PDD) and beam/dose profile (BP) for 6 MV and 18 MV photon beams for different field sizes and for different Skin-Source-Distance (SSD), and to compare the measured results with the results calculated by Treatment Planning Systems (TPS). The measured results of (PDD) and (BF) are consistent with those calculated by TPS, which allows us to conclude that the linear accelerator at oncology Center in Nouakchott is in good condition. Other Parameters: (energy, (SSD) and field sizes) have been also studied in this work, in order to perform a comprehensive quality study for this accelerator a unique oncology at Mauritania.

Authors and Affiliations

Ould Mohamed Yeslem Ahmed El Mouna, Ould Cheibetta Moussa, Choukri Abdelmajid, Ghassoun Jilali, Hakam Oum Keltoum, Semghouli Slimane

Keywords

Related Articles

Assessment of Biochemical Changes in Pregnancy Induced Hypertension (PIH) among Saudi Population at KAMC-Riyadh

Background: One of the most common complications that affect around 2-5% pregnant women is elevated blood pressure defined as gestational hypertension. Aims & Objective: To compare and correlate between plasma urea, cre...

Iron Deficiency among Pregnant Women Attending Antenatal Clinic at the KNUST Hospital, Kumasi, Ghana

Background: Pregnant women constitute a high risk group for iron deficiency due to increased iron requirements for foetal and maternal tissues growth. This study sought to find out the prevalence of iron deficiency among...

Alzheimer Disease and Environmental Exposure to Neurotoxic Factors: A Controversy

Background: Common neurodegenerative diseases including Alzheimer disease are a major public health issue because of their high prevalence and etiopathogenic complexity. Ageing, combined with a genetic predisposition and...

Alkaline Phosphatase Isoenzymes and Leukocyte Alkaline Phosphatase Score in Patients with Acute and Chronic Disease: A Brief Review

Aims: To conduct a review of the literature concerning existing methods to detect alkaline phosphatase (ALP) in human serum and to examine the dietary factors that modulate ALP-intestinal isoenzyme (IAP) activity, in lig...

Symptomatic Papillary Fibroelastoma- Case Report and Literature Review

Primary cardiac tumors represent a small subset of cardiac neoplasms. The papillary fibroelastoma (PFE) is a benign tumor that typically affects the cardiac valvular system and is second in prevalence only to myxomas. Th...

Download PDF file
  • EP ID EP311739
  • DOI 10.9734/BJMMR/2017/33918
  • Views 54
  • Downloads 0

How To Cite

Ould Mohamed Yeslem Ahmed El Mouna, Ould Cheibetta Moussa, Choukri Abdelmajid, Ghassoun Jilali, Hakam Oum Keltoum, Semghouli Slimane (2017). Preliminary Results of Quality Control for Linear Accelerator at Oncology Center in Nouakchott. Journal of Advances in Medicine and Medical Research, 22(2), 1-8. https://europub.co.uk/articles/-A-311739