Proximal Humerus comminuted fracture: Treated with locking compression plate and fibular strut autograft: A case report

Journal Title: International Journal of Medical and Health Research - Year 2019, Vol 5, Issue 4

Abstract

Comminuted fracture of proximal humerus with limited bone stock in young adults is challenging. There are various modes of fixation for proximal humerus fracture such as percutaneous Kirshner wiring, screw fixation, plating, intramedullary nail fixation and hemiarthroplasty. We reported a four-part proximal humerus fracture treated with locking compression plate and fibular strut autograft. Our purpose was to augment pull-out strength of the locking screws and increase stability of the construct.

Authors and Affiliations

Ramesh Muthu, Muhammad Nirmal, Agus Foead, Thevarayan ,, Sazali Salleh

Keywords

Related Articles

Comparison of estimation of fetal weight by two clinical methods and ultrasound at term pregnancy

Objective: To make a comparative evalution of estimation of fetal weight in term pregnancy by using USG and Johnson’s formula and Dare’s formula. Methods: The fetal weight in –utero was calculated by using the above meth...

Pneumocystis jiroveci Pnemonia in Systemic Lupus Erythematosus: A Case report

Pneumocystis jiroveci pneumonia (PJP), formerly known as Pneumocystis carinii pneumonia (PCP) is the most common opportunistic infection in immunocompromised patients including patients with systemic lupus eythematosus (...

Comparative study between some different serological methods for detection of Hepatitis "C" virus antibodies in Taif Governorate

Objective: detection of hepatitis C virus antibodies in serum samples can be done by different methods. However, choosing between them is still a confusing matter. So, this study aimed to make a comparison between some s...

Nerve conduction study for early detection of leprosy

Background: Patient with wrist-drop and foot-drop was biopsied for mononeuritis multiplex. Diagnosis leprosy, came surprising as it was eliminated. Thus prompted, did research on electrophysiology data of leprosy patient...

Monitored anaesthesia care with dexmedetomidine or paracetamol for patients undergoing vitreo-retinal surgeries under sub-tenon’s anaesthesia

The needleless sub-tenon’s block is being increasingly used for vitreo retinal surgeries. The present study is to evaluate the safety and efficacy of “needleless” regional anaesthesia through the sub-tenon route for vitr...

Download PDF file
  • EP ID EP585516
  • DOI -
  • Views 152
  • Downloads 0

How To Cite

Ramesh Muthu, Muhammad Nirmal, Agus Foead, Thevarayan, , Sazali Salleh (2019). Proximal Humerus comminuted fracture: Treated with locking compression plate and fibular strut autograft: A case report. International Journal of Medical and Health Research, 5(4), 101-103. https://europub.co.uk/articles/-A-585516