Qualitative Parameters of Guyed Chimney Interaction with Anchor Foundations

Journal Title: Металлические конструкции - Year 2016, Vol 22, Issue 3

Abstract

The effect of ground deformation of anchor foundation on stresses and strains in steelworks is dealt with in the paper including guyed steel chimney. The horizontal deformations of ground are modeled by inducing differential movements of a separate foundation in horizontal planes. The guy reactions and bending moments in a chimney shell due to movement are calculated. The most widespread types of chimney of 75 and 100 m high with guys at one or two levels having the horizontal angle of 120° are adopted as the object for research. The calculation model of the structure is a 3D system. The qualitative parameters for the influence of differential soil deformations on guy reactions and internal forces into the chimneys are obtained and analyzed. It demonstrated that there is a linear relation between translations and forces for displacements up to 0.1 m. On the basis of numerical data received the model are proposed and the limit values of displacements are obtained.

Authors and Affiliations

Vadim Gubanov, Alexander Golikov

Keywords

Related Articles

Numerical researches complex of multifaceted composite elements under axial compression

In the article the relevance of creating multifaceted pipe-concrete structures (MPCS), associated with the possibility of their use in urban construction as structures that meet high modern demands for their aesthetics a...

Qualitative Parameters of Guyed Chimney Interaction with Anchor Foundations

The effect of ground deformation of anchor foundation on stresses and strains in steelworks is dealt with in the paper including guyed steel chimney. The horizontal deformations of ground are modeled by inducing differen...

Accounting of Joint Work of Thin-Sheet Membranes with Fastening of the Stabilizer System

The article considers the existing methodology for determining the effective width of the plate when working together and reinforcing stiffener sheet membrane coating, including – the method of reduction ratios. It has b...

The Loads and Actions Effects on the Decision of Narrow-Band Antenna Support Design Shape

The article analyzes the impact of loads and actions effects on the decision of narrow-band antenna support design shape of radio relay communication, it has been analyzed the group of tower supports on the design of the...

Comparative Analysis of the Calculation of an I-Beam Cross-Section Beam According to Eurocode 3 and SNiP II-23-81*

The article presents a comparative analysis of the beams of the I-beam cross-section according to Eurocode 3: “Steel structures” [1] and SNiP II-23-81* “Steel structures” [6]. The object of investigation was a beam of an...

Download PDF file
  • EP ID EP448583
  • DOI -
  • Views 119
  • Downloads 0

How To Cite

Vadim Gubanov, Alexander Golikov (2016). Qualitative Parameters of Guyed Chimney Interaction with Anchor Foundations. Металлические конструкции, 22(3), 115-124. https://europub.co.uk/articles/-A-448583