Quality assurance of modern image guided 3D-conformal radiotherapy treatments

Journal Title: Journal of Medical and Scientific Research - Year 2014, Vol 2, Issue 2

Abstract

Purpose: To describe the Quality Assurance (QA) methods of modern Three-dimensional conformal radiotherapy (3DCRT) treatments such as image guided Intensity-modulated radiation therapy (IMRT), RapidArc, Stereotactic radiosurgery (SRS)/ Stereotactic fractionated radiation (SRT) to ensure quality of treatments delivered to cancer patients. Materials and methods: 3D-RFA and Ionisation chambers were used for the machine specific QA. Imatrixx-2D array with locally fabricated phantom and another locally fabricated spherical phantom with ionization chambers is used for relative and absolute QA respectively. Electronic Portal Imaging Devices and Epiqa software is used for the QA with portal dosimetry. Varians Eclipse and Brainlab’s Iplan treatment planning systems were used for treatment plans and dose calculations. For relative dosimetry the planar dose matrices are analysed using global Gamma Index criteria of 3mm distance to agreement (DTA) and 3% dose difference. The QA of Machines and patient treatments were carried out using national and international protocols. Results: The maximum deviations of percentage of dose points in which γ>1 are 1.98 in relative dosimetric QA and 1.5 for absolute QA in the delivery of IMRT, RapidArc and SRS/SRT treatments. The mean deviations and Standard deviation (SD) values are less in portal dosimetry than that of phantom studies in relative dosimetry and all the absolute dose deviations are less than that of relative dose deviations. Conclusion: The results of machine specific QA as well as relative and absolute dosimetric QA of patient treatments are well within the acceptable limits of values mentioned in the national and international protocols. The study ensures the accuracy and quality of the treatments delivered to the patients at our oncology center.

Authors and Affiliations

Krishnamurthy K, Babu AA, Prasad PBLD, Arasu KK

Keywords

Related Articles

Post-surgical giant pseudo meningocele in a patient with cervical neurofibroma: Case report and literature review

A patient aged 48-year-old, presented to the outpatient department with neck pain and weakness of all the limbs for three months. On examination, he had power 3/5 in all the limbs with bilateral hand grip weakness of 50%...

Imaging in fibrous dysplasia

Abstract is not available for this article

Tumor lysis syndrome – An overview and current perspective

Tumor lysis syndrome (TLS) is an oncological emergency where in spontaneous or treatment-induced cell death leads to a constellation of metabolic abnormalities that can result in potentially life threatening complication...

Robotic surgery a boon in medical science

Objectives: To compare the outcomes of robotic assisted laparoscopic versus open hysterectomy with pelvic lymphadenectomy in endometrial cancer. Methods: Prospective analysis done for the two cohorts underwent hysterect...

Monitoring of pulmonary function in people dwelling and working in and near cement factory area

Indian cement industry is the second largest in the world. With growing industrialization more and more people are involved in industrial occupation, who are prone to serious health hazards. In the present study we focus...

Download PDF file
  • EP ID EP608679
  • DOI 10.17727/JMSR.2014/2-011
  • Views 58
  • Downloads 0

How To Cite

Krishnamurthy K, Babu AA, Prasad PBLD, Arasu KK (2014). Quality assurance of modern image guided 3D-conformal radiotherapy treatments. Journal of Medical and Scientific Research, 2(2), 57-61. https://europub.co.uk/articles/-A-608679