Quantitative ocular-motor tests analysis in Multiple Sclerosis
Journal Title: Otolaryngologia Polska - Year 2010, Vol 64, Issue 3
Abstract
Abnormalities in the ocular-motor refl ex recorded in electronystagmography may indicate central vestibular system impairment. Multiple sclerosis (MS) is the most common chronic, debilitating disease characterized by focal demyelinization that develops throughout the central nerves system at varying time. The aim of the study was to apply the quantitative analysis of ocular-motor tests to evaluation degree of the central system impairment in MS patients. Material and methods: The study was carried on 60 MS patients consulted in Balance Division, Otolaryngology Clinic, Medical University of Lodz, from 2002 to 2004, and 50 healthy persons as the control group. Clinical otoneurolaryngological examinations and electronystagmography tests (smooth pursuit, optokinetic, saccades) were performed in all patients. We apply the quantitative Z score analysis for gain in smooth pursuit test, slow phase velocity in optokinetic, maximal velocity of the saccades. Depending on Z score value the patients were qualifi ed into one of three scale dysfunctions. Results: Statistical correlation were found between results of all ocular-motor tests outcome in MS patients and control group. In smooth pursuit test most often second degree (35.0%), in OKN test fi rst degree (28.3%) and in saccades the third degree (31.6%) of dysfunction was observed. The higher the values of Z score, the more abnormal results of ocular-motor refl ex were observed. Conclusion: Application of the quantitative Z score analysis of the ocularmotor tests results demonstrating the degree of central ocular-motor system dysfunction in MS patients. This method may assist in monitoring the central vestibular system impairment and in evaluation course of the disease and degree of neurological disability.
Authors and Affiliations
Magdalena Józefowicz-Korczyńska, Marcin Durko, Anna Pajor
Ocena wartości diagnostycznej testu skrętu szyi w badaniach obiektywnych u chorych z zawrotami głowy i/lub niedosłuchu
Wprowadzenie: Celem pracy była ocena wartości diagnostycznej testu skrętu szyi w badaniach obiektywnych u chorych z zawrotami głowy i/lub niedosłuchem. Materiał i metody: Badania przeprowadzono u 100 chorych, w tym u 54...
Ekspresja koreceptorów CD80 i CD86 na limfocytach B w przerosłych migdałkach gardłowych u dzieci chorych na wysiękowe zapalenie ucha środkowego
Aim: The aim of this study was evaluation of the percentage and mean fluorescence intensity of lymphocytes B with expression CD80 and CD86 in hypertrophied adenoids in children with otitis media with effusion. Material a...
Ocena przydatności badania 18F-FDG PET/CT w diagnostyce nowotworów głowy i szyi
SUMMARY Objectives: The aim of the study was to determine the usefulness of 18F-FDG PET/CT in oncological diagnostics in laryngology. Material and methods: 45 PET/CT examinations were performed in 41 pa-tients diagnosed...
Complications of radio- and radiochemotherapy in patients undergoing major salivary gland cancer surgery
Purpose: The aim of this retrospective study was to present the prevalence of early and late radiation-induced reaction and factors affecting its formation and severity in patients after adjuvant radio- or radiochemother...
Usefulness of high frequency audiometry (HFA) in qualifi cations person to work in noise on high intensity