Radiometric modulation measuring device of intensity of optical radiation

Abstract

Introduction. The paper proposed a block diagram of radiometric measuring the intensity of optical radiation from modulation conversion parameter input . To assess the intensity of use periodically comparing the reference signal (shaded) and measurement (open) photodi-odes. Studies. The proposed radiometric modulation meter provides increased sensitivity and measurement accuracy by reducing the influence of dark current measurement and reference photodiodes and compensation intrinsic noise measuring channel through their periodic anti-phase comparison.

Authors and Affiliations

A. Yanenko, S. Mikhailenko

Keywords

Related Articles

Structurally technical the aspects of measuring of concentration of easy aeroions are In-process considered the method of the opened collector

Вasic methods of measuring of concentration of easy aeroions, the features of their use, advantage, and failings are certain. It is suggested to use the method of the opened collector for measuring the concentration of e...

Frequency modulated signal generation

Compound frequency modulated signal generation process with simple integrated direct digital synthesis microcircuit is presented starting DDS microcircuit choice, time and modulation characteristics analysis, interface u...

Zone diagram formation of photon and phonon crystals

Inroduction. Photon and phonon crystals are crystal structures, which just like the crystals, are characterized by zone spectral properties. The purpose of the article is to research the input impedance characteristics a...

Comparative analysis of methods for testing software of radio-electronic equipment

The analysis of the concepts of quality and reliability of software products that are part of the radio-electronic equipment is making. Basis testing methods of software products that are used in the design of hardware a...

Application of correlation matrix for solving the task of authentification of person after the dinamically entered signature

The work of method with use of correlation matrix for solving the task of authentification of person after the dinamically entered signature is illustrated.

Download PDF file
  • EP ID EP308959
  • DOI 10.20535/RADAP.2014.56.96-101
  • Views 54
  • Downloads 0

How To Cite

A. Yanenko, S. Mikhailenko (2014). Radiometric modulation measuring device of intensity of optical radiation. Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування, 0(56), 96-101. https://europub.co.uk/articles/-A-308959