Research of frequency descriptions, parameters conductometric differential sensors with pectinate topology

Abstract

In differential conductometric systems, for example in biosensor systems, often use co-planar thinly-pellicle structure double-sensors with pectinate topology. Simple and useful devices could be realized with help of them. But sensitivity and producibility of results those devices depends on parameters of sensors which we probe. On base of metrological research frequency descriptions, parameters conductometric differential sensors was analyzed effectiveness of using this sensors with different geometrical parameters and materials for better descriptions of biosensor system with them.

Authors and Affiliations

D. Makarov, V. Melnik

Keywords

Related Articles

Scattering of Electromagnetic Pulses on Different Dielectric Resonator Systems

The theory of scattering of electromagnetic pulses in a transmission line on systems of coupled dielectric resonators of different shapes and dielectric permittivity is developed. General analytic expressions for envelop...

Identification of a semiconductor by facility of the nonlinear location on two harmonicas

In article is brought theoretical explanation of a experimentally received effect of the occurrence the negative differential resistance on the volt-ampere characteristic of a diode structures at influence upon them comp...

Neural-genetic method for synthesis of antennas and microwave devices

A neural-genetic concept is proposed for synthesis of antennas and microwave devices. A device to be optimized is modeled by artificial neural networks and synthesis is made by genetic algorithm based inversion of the ar...

Frequency components with negative resistance for embedded measurement systems

The aim of the given paper is a critical analysis of the prospects of further development of the frequency components with negative resistance. The possible and most promising areas of the development of new and improve...

The analysis of linear parametric circuits with switched capacitors by compact modified method of curve fitting

The analytical connections  between the topological resistive element’s connection matrix of ARC-prototype and the topological switched capacitor’s connection matrices of resistor’s switch-capacitor  equivalents   for bo...

Download PDF file
  • EP ID EP309315
  • DOI 10.20535/RADAP.2011.45.139-145
  • Views 54
  • Downloads 0

How To Cite

D. Makarov, V. Melnik (2011). Research of frequency descriptions, parameters conductometric differential sensors with pectinate topology. Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування, 0(45), 139-145. https://europub.co.uk/articles/-A-309315