Radon in Workplaces the Urgent Need of New Measurements and Devices.

Abstract

The existing passive radon monitors, their relative calibration facilities together with the past intercomparison exercises have been mission-oriented towards radon measurements in dwellings. These monitors have been successfully applied throughout the world for radon measurements in homes, characterized by temperatures in the range from 20 to 25°C and a relative humidity less than 50 R.H. A multitude of different problems may arise when these passive monitors are used in an environment other than homes, such as in soil and in workplaces, where large humidity up to 100 RH and temperatures anywhere from 0°C to 40°C may be encountered. Under severe environmental conditions, different measurement errors may occur which have remained concealed to date. These errors may be caused by a drastic change of both the radon diffusivity through them and for the monitor housing respectively. permeation membranes or the radon absorption by the plastics, used for the track detector. For compliance with the assessment of the occupational exposures, it is necessary to eliminate all the possible sources of errors, which may be conducive to litigation. Another important shortcoming of the existing passive monitors is difficult to turn them on/off daily, as required for radon measurements in workplaces. Finally, most of the problems, listed above, can be solved by the exploitation of a new generation of passive monitors, known as Rn film-badges. These monitors are similar and often identical to neutron film-badges, which have proved to be very successful throughout the world for the personnel neutron dosimetry. In particular, the present paper will describe the unique characteristics of these radon film badges, such as compactness, fast time response, any desired response sensitivity, simplicity in turning them on and off, etc.

Authors and Affiliations

L Tommasino, G Espinosa

Keywords

Related Articles

Analysis of the Lepton Mixing Matrix in the Two Higgs Doublet Model

In the theoretical framework of Two Higgs Doublet Model (2HDM) plus three right-handed neutrinos we consider a universal treatment for the mass matrices, aside from that the active neutrinos acquire their small mass thro...

Probable Projectile-Target Combinations for the Synthesis of Super Heavy Nucleus 286112

The fusion cross sections for the reactions of all the projectile-target combinations found in the cold valleys of 286112 have been studied using scattering potential as the sum of Coulomb and proximity...

Mini Subcritical Nuclear Reactor

A mini subcritical nuclear reactor was designed using Monte Carlo methods. The reactor has light water as moderator, natural uranium as fuel, and a 239PuBe neutron source. In the design uranium fuel was modeled in an arr...

Effect of Al and Mg Doping on Optical Properties of ZnO Thin Films Prepared by Spin Coating

This paper investigated the influence of aluminum and magnesium doping on the optical and electrical properties of zinc oxide (znO) thin films for solar cell application. zinc acetate dehydrates was used as starting mate...

Alignment Studies for Tungsten Near L3 Sub-Shell Threshold Via Theoretical, Experimental and Empirical Methods

Alignment studies are made for tungsten near L3 sub-shell threshold using theoretical, experimental and empirical approaches. Experimentally to measure alignment parameter, the angular distribution of L x-rays of tungste...

Download PDF file
  • EP ID EP569037
  • DOI 10.15415/jnp.2018.61001
  • Views 185
  • Downloads 0

How To Cite

L Tommasino, G Espinosa (2018). Radon in Workplaces the Urgent Need of New Measurements and Devices.. Journal of Nuclear Physics, Material Sciences, Radiation and Applications, 6(1), 1-7. https://europub.co.uk/articles/-A-569037