Real-Time Supraventricular Tachycardia Monitoring System Using Closed-Loop Control

Abstract

In this paper a unique issue rising from feedback control of Supraventricular Tachycardia monitoring system with embedded communication channels has been investigated. One of the important factors to measure the performance of the feedback control closed loop system is disturbance and noise attenuation factor. It is important that the feedback system can attenuate such disturbances on the Supraventricular Tachycardia heart rate signals. Since signal estimation is updated on the arrival of new data, its dynamics actually change with the sampling interval. Consequently, interaction among sampling, signal estimation, and the controller will introduce new issues in remotely controlled Supraventricular Tachycardia system. This paper treats a remotely controlled Supraventricular Tachycardia system with one communication channel which connects between the heart rate and rhythm measurements to the remote controller. Typical and optimal signal estimation schemes is represented by a signal averaging filter with its time constant derived from the step size of the signal estimation algorithm.

Authors and Affiliations

Mohammad A. Obeidat, Ayman M Mansour

Keywords

Related Articles

Closed Loop Control of Composite Dc-Dc Converter for Electric Vehicle

In a electric vehicle powertrain, a boost dc-dc converter enables reduction of the size of the electric machine and optimization of the battery system. Design of the powertrain boost converter is challenging because the...

Selective Harmonic Elimination in a Conventional Single Phase Full-Bridge Inverter with Adjustable Output

Ordinary single-phase inverter gives a square wave output which when applied to electrical appliances may damage the later, reduce its efficiency as well as life as this inverter output waveform is not sinusoidal and con...

Circuit Level Performance of FETS: A Comparative Study of Propagation Delay with Half Adder

This paper deals with the propagation delay comparison of half adder with different FETs; such as MOSFET, CNTFET, FINFET. Nanotechnology is the promising field which functions at the molecular level to replace the conven...

Network Reconfiguration in Distribution Systems Using Harmony Search Algorithm

This manuscript explores feeder reconfiguration in distribution networks and presents an efficient method to optimize the radial distribution system by means of simultaneous reconfiguration. Network Reconfiguration of ra...

Design of the Pulse Oximetry Measurement Circuit and Its Sensing System Based On CMOS

The pulse oximetry circuit and its sensing system is designed based on the standard CMOS technology of 0.18um. The reflection oxygen sensor is used to collect the pulse oximeter signal of human body, then the collected p...

Download PDF file
  • EP ID EP388518
  • DOI 10.9790/1676-1301010516.
  • Views 124
  • Downloads 0

How To Cite

Mohammad A. Obeidat, Ayman M Mansour (2018). Real-Time Supraventricular Tachycardia Monitoring System Using Closed-Loop Control. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(1), 5-16. https://europub.co.uk/articles/-A-388518