Real-Time Supraventricular Tachycardia Monitoring System Using Closed-Loop Control

Abstract

In this paper a unique issue rising from feedback control of Supraventricular Tachycardia monitoring system with embedded communication channels has been investigated. One of the important factors to measure the performance of the feedback control closed loop system is disturbance and noise attenuation factor. It is important that the feedback system can attenuate such disturbances on the Supraventricular Tachycardia heart rate signals. Since signal estimation is updated on the arrival of new data, its dynamics actually change with the sampling interval. Consequently, interaction among sampling, signal estimation, and the controller will introduce new issues in remotely controlled Supraventricular Tachycardia system. This paper treats a remotely controlled Supraventricular Tachycardia system with one communication channel which connects between the heart rate and rhythm measurements to the remote controller. Typical and optimal signal estimation schemes is represented by a signal averaging filter with its time constant derived from the step size of the signal estimation algorithm.

Authors and Affiliations

Mohammad A. Obeidat, Ayman M Mansour

Keywords

Related Articles

Performance Analysis of Dstatcom in Live Distribution System for Load Compensation

Power Quality issues are the major concern in the low voltage distribution system. The paper suggests a shunt connected custom power device (DSTATCOM) to provide load compensation in the 3-phase, 4- wire network. The per...

Design and Realization of Readout for Beam Loss Detector of Accelerator Particles

During construction of the accelerator machine to achieve optimal transmission, the fraction of beam particles lost has to be controlled. It is why a careful analysis of the location and time structure of possible losses...

Review of HVDC Circuit Breakers Topologies.

Voltage Source Converter-High Voltage Direct Current (VSC-HVDC) is the most efficient and reliable method for electrical power transmission over long distances. The greatest challenge with VSC-HVDC system is that short-c...

Performance Evaluation of Wide Band Channel At 900 MHz Using Lee Model

In this paper, deterministic model using a Lee model developed for use at 900MHz and has two modes which is also used to characterize a wide band propagation channel in terms of received signal strength from which we com...

Dendrite Growth Model at Bonded (001) GaAs Interface

A periodic GaAs wafer-bonded structure was used for nonlinear optical device. Results showed voids present at the bonded GaAs twin boundary. These voids were caused by natural topographical irregularities and surface con...

Download PDF file
  • EP ID EP388518
  • DOI 10.9790/1676-1301010516.
  • Views 133
  • Downloads 0

How To Cite

Mohammad A. Obeidat, Ayman M Mansour (2018). Real-Time Supraventricular Tachycardia Monitoring System Using Closed-Loop Control. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(1), 5-16. https://europub.co.uk/articles/-A-388518