Real-Time Supraventricular Tachycardia Monitoring System Using Closed-Loop Control

Abstract

In this paper a unique issue rising from feedback control of Supraventricular Tachycardia monitoring system with embedded communication channels has been investigated. One of the important factors to measure the performance of the feedback control closed loop system is disturbance and noise attenuation factor. It is important that the feedback system can attenuate such disturbances on the Supraventricular Tachycardia heart rate signals. Since signal estimation is updated on the arrival of new data, its dynamics actually change with the sampling interval. Consequently, interaction among sampling, signal estimation, and the controller will introduce new issues in remotely controlled Supraventricular Tachycardia system. This paper treats a remotely controlled Supraventricular Tachycardia system with one communication channel which connects between the heart rate and rhythm measurements to the remote controller. Typical and optimal signal estimation schemes is represented by a signal averaging filter with its time constant derived from the step size of the signal estimation algorithm.

Authors and Affiliations

Mohammad A. Obeidat, Ayman M Mansour

Keywords

Related Articles

Initial Development and Testing of Microcontroller-MQ2 Gas Sensorfor University Air Quality Monitoring

Typical air quality monitoring system involved the use of expensive instruments often accessed through the Philippines Department of Environment and Natural Resources (DENR), leading to limitedlocale based air quality mo...

Analysis of Silicon Clad Optical Waveguide for High Extinction Ratio TE/TM Pass Polarizers using Resonant Coupling between Guided Modes and Lossy Modes

Attenuation characteristics of a planar silicon-clad ion exchange glass waveguide structure are investigated theoretically at the optical wavelength of 0.6328 µm. An oscillatory behaviour of the attenuation curves is not...

Effect of faulty section isolation process on the reliability of DG connected Distribution System

The present energy problem may be overcome by Distributed Generation (DG) using distributed renewable energy sources. DG helps to improve the reliability of the distribution system. When DG is used as back up generation,...

Hydro Power Generation In Nigeria, Environmental Ramifications

Electricity is the bedrock of every nation development and can be transported instantaneously & pollution free at consumer end. There are three hydro power generating stations that contribute to the nation’s grid, namely...

Mechatronic Control Model of an inverted pendulum

The inverted pendulum, a popular mechatronic application, is considered as a special class of unstable, non-linear, multivariable and complex mechatronic systems with two degrees of freedom and a single control input. Th...

Download PDF file
  • EP ID EP388518
  • DOI 10.9790/1676-1301010516.
  • Views 130
  • Downloads 0

How To Cite

Mohammad A. Obeidat, Ayman M Mansour (2018). Real-Time Supraventricular Tachycardia Monitoring System Using Closed-Loop Control. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(1), 5-16. https://europub.co.uk/articles/-A-388518