Real-Time Supraventricular Tachycardia Monitoring System Using Closed-Loop Control

Abstract

In this paper a unique issue rising from feedback control of Supraventricular Tachycardia monitoring system with embedded communication channels has been investigated. One of the important factors to measure the performance of the feedback control closed loop system is disturbance and noise attenuation factor. It is important that the feedback system can attenuate such disturbances on the Supraventricular Tachycardia heart rate signals. Since signal estimation is updated on the arrival of new data, its dynamics actually change with the sampling interval. Consequently, interaction among sampling, signal estimation, and the controller will introduce new issues in remotely controlled Supraventricular Tachycardia system. This paper treats a remotely controlled Supraventricular Tachycardia system with one communication channel which connects between the heart rate and rhythm measurements to the remote controller. Typical and optimal signal estimation schemes is represented by a signal averaging filter with its time constant derived from the step size of the signal estimation algorithm.

Authors and Affiliations

Mohammad A. Obeidat, Ayman M Mansour

Keywords

Related Articles

Removal of EMG Artifacts from Multichannel EEG Signal Using Automatic Dynamic Segmentation and Adaptive Thresholding with Multilevel Decomposed Wavelets

Background: Like the brain, muscles also generate electrical signals. These signals are picked up by EEG electrodes and become muscle artifacts in EEG recording. MA is looking like fast oscillations. EEG signals disturbe...

Recent Trends and Improvisations in FPGA

With the improvements of VLSI design in FPGA, the application areas got wider. The FPGAs architectural developments afford FPGA developers to produce effective devices day-by-day. Today these applications wider from comm...

Design of power system stabilizer for damping power system oscillations

The problem of the poorly damped low-frequency (electro-mechanical) oscillations of power systems has been a matter of concern to power engineers for a long time, because they limit power transfers in transmission lines...

Intelligent Secured Garage for Smart Buildings

Huge traffic in INDIA is due to improper parking system at various places like theatres, apartments, supermarkets etc. This forces the people to park their vehicle on roads. The present project work deals with the automa...

Evaluating the Performance of Unified Power Flow Controller (UPFC) On Fault Current Limitation in the Nigrian 330kv Power System.

The Performance of Unified Power Flow Controller (UPFC) on Fault Current Limitation in a 330kV Power Network. The SIMULINK model of the Nigerian 330kV system was developed and the model of the UPFC was developed and inte...

Download PDF file
  • EP ID EP388518
  • DOI 10.9790/1676-1301010516.
  • Views 137
  • Downloads 0

How To Cite

Mohammad A. Obeidat, Ayman M Mansour (2018). Real-Time Supraventricular Tachycardia Monitoring System Using Closed-Loop Control. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(1), 5-16. https://europub.co.uk/articles/-A-388518