Abstract

The paper addresses the power consumption profile of the University of Nigeria, Nsukka. The electricity bill of the institution which has existed for over fifty years is N14.4m on average which the University Administration sees as very excessive. The paper investigates the reasons for this high cost of electricity bills and seeks for ways to reduce these excessive bills. Load audit assessment has been adopted for the study. Audit result obtained shows that obsolete lighting loads were prevalent in the system, and non-lighting loads were based on very old technology which accounted for the high energy consumption. The result of this work shows 83% reduction for both lighting and non-lighting loads audit which translates to an average N11m cost savings for the monthly electricity bill. The paper shows 58.2% consumption in Staff Quarters, 27.77% in the Hostels while Faculties and the Administrative blocks take 11.85% and 2.18% consumption respectively.

Authors and Affiliations

U. O. Orji, T. C. Madueme

Keywords

Related Articles

Design of 10-bit current steering DAC with binary and segmented architecture

This paper presents the design of 10-bit current steering DAC of binary and segmented architectures with 400MHz clock frequency. This circuit is designed in 130nm technology; with a supply voltage of 3.3V.This design is...

1/f noise study as a non-destructive test to check MOSFET

1/f noise studies play significant role in choosing the band of frequency in which a device can be commendably used. This property is used to check the MOSFET without disturbing its physical structure. A MOSFET is used f...

Heuristic Approach to DG Sizing and Siting in Distribution System for Voltage Drop Reduction

This paper presents the impact of penetration level and power factor of DG on the voltage drop in a distribution system. For this purpose, suitable expressions have been developed to estimate the squared voltage drop red...

Resilience of Electric Power Distribution Networks to N-1 Contingencies: The Case of Sekondi-Takoradi Metropolis

Contingency situation is an abnormal conditionthat do occur in an electric power distribution networks. It puts whole system or a part of the system under stress. It occurs due to sudden opening of a transmission line, g...

Selective Harmonic Elimination in a Conventional Single Phase Full-Bridge Inverter with Adjustable Output

Ordinary single-phase inverter gives a square wave output which when applied to electrical appliances may damage the later, reduce its efficiency as well as life as this inverter output waveform is not sinusoidal and con...

Download PDF file
  • EP ID EP388248
  • DOI 10.9790/1676-1204041118.
  • Views 121
  • Downloads 0

How To Cite

U. O. Orji, T. C. Madueme (2017). Electric Power Consumption Reduction in the University of Nigeria, Nsukka Power Network. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 12(4), 11-18. https://europub.co.uk/articles/-A-388248