Adjustment of Logic Operational Chemical Injection Pump in pH Control of Water Steam Cycle to Improve Steam Turbine 5.8 Reliability of Power Plant PT. PJB UP Muara Tawar

Abstract

Water quality in power plant is the main factor of equipment reliability. Standard water quality can assure performance of equipment and minimize equipment defact especially from corrosion. In Block 5 UP Muara Tawar, water is used to producing steam from HRSG. Actually pH for HP drum is 30% above the upper limit. To overcome this problem, it is needed to do some adjustment with the method as follows: data collection from process information system, brainstorming with operation, engineering and instrumentation to improve quality of water for short and long term period of operation, perform temporary corrective maintenance by Operate CBD in higher opening Operate phospate chemical injection manually based on pH set point or regulate based on time, literature review about logic system of phospate chemical injection in drum and make a research plan to find source of problem. From adjustment of operational logic injection pump the pH and conductivity value is under control in both higher and lower limit. It is shown that pH value are laid in 9.0-9.4. Moreover, the actual conductivity value are about 7.23 µs /cm and 21.34 µs /cm, respectively. It is match with ABB conductivity limit i.e. maximum 40 µs /cm. Morover, water consumption decrease from 6413 m3/days to 45.1 m3/days

Authors and Affiliations

Erlangga . , Ali Sandra, Faris Azharuddin, Riski Aditya, Kevin Sanjoyo Gunawan, Totok R. Biyanto

Keywords

Related Articles

Novel Three Phase Five Level Inverter with Reduced Number of Power Electronics Components

Novel three phase five level inverter with reduced number of power electronics components are introduced. This inverter consists of typical three phase two level-bridge inverter with three bidirectional switches and two...

Portable Smart Phone Charger Using Human Mechanical Energy by Gear Train with Hand Crank

Mobile phone is our means to remain connected. While the phones have progressively got more powerful processors and large touch screen interfaces, their power requirement has increased correspondingly. Unfortunately, bat...

Microcontroller Based Colour Identification System

A microcontroller based system using P89V51RD2 microcontroller for colour identification system is designed and developed. It is based on the principle that the analog voltages of the sensor converted to RGB colours. The...

Effect of Cell Size on the Population, Average Call Time, Subscriber Number Per Call(SNPC) And Call Number Per Hour

When we planning for cell mobile area, we should put in our consider the traffic and the coverage area by doing analysis using the TDMA – FDMA mobile cellular communication system. In this paper we collaborates with Oore...

Accurate Dielectric Capacitance Determination from MetalInsulator-Semiconductor Devices Having Bias and Frequency Dependent Conductance Due To Leakage Current

A model for MIS device in accumulation is proposed which includes a bias and frequency dependent conductance in parallel with the insulator capacitance due to the leakage current. The model is validated by experimental r...

Download PDF file
  • EP ID EP387312
  • DOI 10.9790/1676-1203050409.
  • Views 121
  • Downloads 0

How To Cite

Erlangga . , Ali Sandra, Faris Azharuddin, Riski Aditya, Kevin Sanjoyo Gunawan, Totok R. Biyanto (2017). Adjustment of Logic Operational Chemical Injection Pump in pH Control of Water Steam Cycle to Improve Steam Turbine 5.8 Reliability of Power Plant PT. PJB UP Muara Tawar. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 12(3), 4-9. https://europub.co.uk/articles/-A-387312