Real world application of a smartphone-based visual acuity test (WHOeyes) with automatic distance calibration

Journal Title: Eye Science (Yanke Xuebao) - Year 2024, Vol 39, Issue 9

Abstract

[Background:] To develop and assess usability of a smartphone-based visual acuity (VA) test with an automatic distance calibration (ADC) function, the iOS version of WHOeyes. [Methods:] The WHOeyes was an upgraded version with a distinct feature of ADC of an existing validated VA testing APP called V@home. Three groups of Chinese participants with different ages (≤20, 20-40, >40 years) were recruited for distance and near VA testing using both an Early Treatment Diabetic Retinopathy Study (ETDRS) chart and the WHOeyes. The ADC function would determine the testing distance. Infrared rangefinder was used to determine the testing distance for the ETDRS, and actual testing distance for the WHOeyes. A questionnaire-based interview was administered to assess satisfaction. [Results:] The actual testing distance determined by the WHOeyes ADC showed an overall good agreement with the desired testing distance in all three age groups (p > 0.50). Regarding the distance and near VA testing, the accuracy of WHOeyes was equivalent to ETDRS. The mean difference between the WHOeyes and ETDRS ranged from -0.084 to 0.012 logMAR, and the quadratic weighted kappa (QWK) values were greater than 0.75 across all groups. The test-retest reliability of WHOeyes was high for both near and distance VA, with a mean difference ranging from -0.040 to 0.004 logMAR and QWK all greater than 0.85. The questionnaire revealed an excellent user experience and acceptance of WHOeyes. [Conclusion:] WHOeyes could provide accurate measurement of the testing distance as well as the distance and near VA when compared to the gold standard ETDRS chart.

Authors and Affiliations

Yi Wu, Stuart Keel, Vera Lúcia Alves Carneiro, Shiran Zhang, Wei Wang, Chi Liu, Xuanzhang Tang, Xiaotong Han, Mingguang He

Keywords

Related Articles

Effect evaluation of ideological and political education in the eight-year clinical medicine ophthalmology integrated curriculum

[Objective:] To investigate the student satisfaction and educational effect of integrating ideological and political elements into the eight-year clinical medicine ophthalmology integrated curriculum. [Methods:] An anony...

Evidence-based analysis of off-label drug use in ophthalmology

[Objective:] To investigate off-label ophthalmic medications, and provide an effective and safe evidence-based reference for the rational use of ophthalmic drugs. [Methods:] On the basis of collecting the off-label drug...

Application of WeChat platform in continuous care of patients with complicated cataract after implantable collamer lens implantation

[Objective:] To explore the application effect of WeChat platform in continuous nursing care for patients with complicated cataract after implantable collamer lens (ICL) implantation. [Methods:] Thirteen patients (16 eye...

Simplifying routine tests before ophthalmic surgeries: Opportunities and challenges in the era of big data

Preoperative routine tests are widely prescribed in clinical settings. However, these tests do not help improving the quality of medical care in low-risk elective surgery. Instead, they are associated with lower efficien...

Related factors analysis and treatment on high intraocular pressure after vitrectomy

Pars plana vitrectomy is one of the common ophthalmic surgeries in clinic practice currently, which is widely used with good therapeutic effect. However, various complications may still occur after operation. Elevated in...

Download PDF file
  • EP ID EP761476
  • DOI 10.12419/24070102
  • Views 22
  • Downloads 0

How To Cite

Yi Wu, Stuart Keel, Vera Lúcia Alves Carneiro, Shiran Zhang, Wei Wang, Chi Liu, Xuanzhang Tang, Xiaotong Han, Mingguang He (2024). Real world application of a smartphone-based visual acuity test (WHOeyes) with automatic distance calibration. Eye Science (Yanke Xuebao), 39(9), -. https://europub.co.uk/articles/-A-761476