Refinement of the mathematical model of frequency converter cable branch with a singlephase short circuit
Journal Title: Восточно-Европейский журнал передовых технологий - Year 2019, Vol 4, Issue 9
Abstract
<p>The mathematical model of the frequency converter cable branch as a part of the mine section power network with a single phase-to-ground fault is clarified. The model takes into account a discrete nature of the output voltage and power switches commutation inertia of a voltage inverter as a part of the converter. A technique is proposed for the formation of a mathematical model of a cable line with distributed parameters as a set of differential equations of state and algebraic coupling equations in matrix form. In this case, the cable is divided into three-phase elementary sections, for a set of typical equivalent circuits of which a graph is built, the matrix of the main sections and the matrix coefficients of the equations are calculated. The latter are solved by numerical methods. This allows to take into account the wave processes in the cable for a high-frequency pulse-width modulated output voltage of the frequency converter. Also the asymmetry of the insulation ground resistance, accompanying a ground fault, is taken into account. The matrix-topological approach allows to avoid operations with partial derivatives with respect to geometric coordinates of the cable. The relevance of the research resulted from the neglect of significant factors in known models, which reduces the accuracy of the analysis. In particular, the influence of the discrete nature of the output voltage of the frequency converter, the distributed nature of the cable line insulation parameters and the transverse asymmetry in emergency mode on the instantaneous values of the ground fault current are not taken into account. As a result of numerical simulation for the network of specific configuration, it was found that the occurrence of ground fault through a human body in the cable branch of the frequency converter is characterized by an unacceptably high probability of fatal electrocution. The monitoring method of the insulation resistance of the power network branch, equipped with the semiconductor frequency converter, is proved. The implementation of the method will improve the electrical safety of underground electrical networks due to the timely detection of insulation damage of the frequency converter cable branch and the transmission of a signal to turn off the supply voltage.</p>
Authors and Affiliations
Sviatoslav Vasylets, Kateryna Vasylets
Forming a defective surface layer when cutting parts made from carbon-carbon and carbon-polymeric composites
<p class="papertitle">We report results of theoretical and experimental research aimed at establishing the mechanisms for the formation of a defective layer at the machined surfaces made from carbon composite materials,...
Analysis of relationship between the dynamics of a thermoelectric cooler and its design and modes of operation
<p>We examined a dynamic model of the relationship between basic parameters and indicators of reliability, taking into consideration the structural and technological elements, for a single-stage cooling device under vari...
Development of thermal installation on the basis of the cascade heat pump for ensuring all thermal and refrigerating needs of the consumer
<p>This article describes the developed and manufactured multifunctional heat point, which allows to supply heat and refrigeration energy to consumers. For effective operation, the heat point contains an automated contro...
Development of methods to control quality of the structure of cross-wound packages
<p>The process of winding is one of the principal processes in the textile industry. Quality of the formed packages largely defines the quality of the finished product in the textile industry, as well as labor productivi...
Studying additional measurement errors from control tools using an integral functional method
<p>Our research has established that under industrial conditions the correction to the result of current measurements when an influencing parameter deviates from the rated value is rarely introduced. In a general case, t...