Reliability Evaluation of Power System SVC Types Using a Markov Chain
Journal Title: روش های هوشمند در صنعت برق - Year 2015, Vol 6, Issue 22
Abstract
Static reactive power compensator (SVC) plays an important role in power system reliability stems. In evaluations of reliability, only reactive power is considered as a constraint network is placed in the SVC BrrsyHa impact on power system reliability evaluation techniques are still not considered. This type of SVC, the TCR-FC, TSC and TCR-TSC examined and the information wrong or repair parts of the states of the user. μ) is expressed.This type of SVC, the TCR-FC, TSC and TCR-TSC examine the error occurs and information HaltHay or repair parts used by our participants .Static reactive power compensator (SVC) plays an important role in power system reliability stems. Thus it is clear that λ is a parameter that indicates the error to each component, and μ is a parameter which indicates the service or go into the same circuit components and repair goes wrong. After the static reactive power compensator (SVC) plays an important role in power system reliability.
Authors and Affiliations
Ali Behdan, Bahador Fani, Ehsan Adib
Optimal Control of Micro-grid (MG) to Improve Voltage Profile Including Combined Heat and Power System
Usually, in the studies of optimal control for the micro-grid with combined heat and power (CHP), economic and environmental goals have been raised. In these studies, the optimization of control devices and compensators...
Design of a 12-Bit 200MS/S CMOS Sample-and-Hold Circuit
In this paper, a new 12bit, 200MS/s fully differential sample and hold circuit is presented. In order to increase the linearity and input voltage dynamic range; bootstrapped-switches are used for sampling the input signa...
Design and Implementation of a High Step-Up Boost-Sepic Hybrid Converter with Soft Switching
In this paper a compound boost- sepic converter with soft switching for high voltage application is proposed. One of the advantages of this converter is that, the main switch is turned on under the ZCS condition without...
New Prognostic Index to Detect the Severity of Asthma Automatically Using Signal Processing Techniques of Capnogram
In this paper, a new prognostic index to detect the severity of asthma by processing capnogram signals is presented. Previous studies have shown significant correlation between the capnogram and asthmatic patient. Howeve...
A Duble Quasi-sinusidal Waveform Elicitation From Matrix Converter Based on Orthogonal Strategy
this paper has scrutinized an effective approach regarding to how to elicit double quasi-sinusoidal waveform with orthogonal angles that can be applicable for two-phase induction motors. Hither, to be more precisely decl...