Reliability Measurement Technique for Evaporator used in Domestic Refrigerators

Journal Title: International Journal of Current Research and Review - Year 2017, Vol 9, Issue 8

Abstract

Introduction: The evaporator used in domestic refrigerator is a heat exchanger in which the heat exchanging occurs by the mean of air. In general the reliability of evaporator is considerably high. It is seen the technical problems arising in evaporator is comparatively lesser than the other components used in it such as compressor, condenser and filter drier etc. But during long run of its use the problems arise in different components of evaporator such as due to leakage of refrigerant, choking or blockage of evaporative coil etc. Aim and Objectives: The aim is to find the reliability of evaporator used in domestic refrigerators, working on the principle of vapour compression refrigeration system. Material and Methods: The data used for analysis is collected from a reliable workshop and a system dynamic method is used for the analysis on Vensim-PLE modeling software. Result: In result output table for year wise reliability of important components are shown. The comparative graph of reliability is also given to easily compare the reliability of each sub components. Conclusion: In this research paper a newer technique is used to calculate the time based reliability of evaporator used in domestic refrigerator. This method of calculation is also applicable for all types of dynamic system. The reliability of evaporator appears almost 95.45% at the end of fifteenth year.

Authors and Affiliations

Vivek Dwivedi

Keywords

Related Articles

Comparison between Laparoscopic High Uterosacralligament Suspension and Laparoscopic Sacrocolpopexy: A Retrospective Study

Background: Pelvic organ prolapse is a latent disease that may take origin after injury of the connective tissue. This investigation aims to compare the surgery outcome of the Laparoscopic High Uterosacral ligament suspe...

Prediction of Potential Lead Molecules through Systematic Integration of Multi-omics Datasets - A Mini-Review

Prediction of a novel or potential lead molecules for a therapeutic drug target without adverse effects is a challenging task in the drug designing, discovery, and development process. The systematic integration of multi...

A Comparative Study of Isolation of Obligate Anaerobes and Facultative Anaerobes in Microbial Flora of Non- Vital Teeth in Diabetic (Type II) and Non-Diabetic Patients

Introduction: The aim of the study was to evaluate and compare the anaerobic microflora (obligate and facultative) of the root canals of non vital teeth with periapical lesions, in diabetic (Type II) and non-diabetic pat...

Total Thyroidectomy for Large Goitres: Case series

Aim: To present the experience of performing Total thyroidectomy for Large Multinodular goitres. Case Report: Series of nine patients with large multinodular goitres treated in our institute between April 2016 and March...

Study of Variation in Repetitive Signature of Same Writer

Comparison of signatures is based on the principle of variation in handwriting as no two signatures are precisely alike. However, due to presence of variation in all handwriting components such as style, slope, slant, al...

Download PDF file
  • EP ID EP604528
  • DOI -
  • Views 128
  • Downloads 0

How To Cite

Vivek Dwivedi (2017). Reliability Measurement Technique for Evaporator used in Domestic Refrigerators. International Journal of Current Research and Review, 9(8), 44-47. https://europub.co.uk/articles/-A-604528