Reliability of performance and associated physiological responses during simulated sprint-distance triathlon

Journal Title: Journal of Science and Cycling - Year 2012, Vol 1, Issue 1

Abstract

Many different methods of simulating triathlon performance in controlled conditions have been developed without establishing the reliability of these assessments. The aim of this study was to determine the reliability of performance and physiological measures during simulated triathlon. Seven trained male triathletes completed initial familiarization, followed by three separate simulated sprint-distance triathlon trials (750 m swim, 500 kJ bike, 5 km run), using a 25 m pool, an electromagnetically braked cycle ergometer and motorized treadmill. Performance (time and mean cycling power) and physiological variables (oxygen uptake, ventilation, heart rate and blood lactate concentration) were measured throughout. Reliability between trials was assessed using one-way analysis of variance (ANOVA), coefficient of variation (CV), intraclass correlation coefficient (ICC) and ratio limits of agreement (LoA). No significant differences were found in performance or physiological variables measured across simulated triathlon trials. High levels of reliability (CV <10% and ICC >0.8) were observed for all performance measures (except transitions) and a majority of physiological variables. Measurement of blood lactate concentration displayed the poorest reliability throughout, with CV’s up to 17.3% and ICC’s as low as 0.4. Ratio LoA for total performance time were similar between trials 1-2 (1.008 */÷ 1.077) and trials 2-3 (1.004 */÷ 1.064). Based on these results simulated sprint-distance triathlon allows for reliable measurement of performance parameters and associated physiological responses in a controlled environment. This reliability data should be considered by simulated triathlon studies when determining statistical power and sample sizes, to allow for more rigorous detection of genuine changes between trials.

Authors and Affiliations

Daniel Taylor*| Lincoln1School of Sports, Coaching and Exercise Science, University of Lincoln, Lincoln, LN6 7TS, United Kingdom., Mark F Smith| Lincoln1School of Sports, Coaching and Exercise Science, University of Lincoln, Lincoln, LN6 7TS, United Kingdom., Veronica E Vleck| CIPER. Faculty of Human Kinetics, Technical University of Lisbon, Cruz Quebrada-Dafundo 1499-002 Portugal.

Keywords

Related Articles

Validity and reproducibility of the Powertap P1 power meter when compared with SRM device

The use of power meters allows the assessment of cycling performance according to the record power profile [1]. Some power meters allow the measurement of power output (PO) in the pedals such as Look Keo Power (Look, Ced...

Comparison of models for the physiological estimation of internal mechanical power in cycling

Physiological models for estimating internal mechanical power (IP) generally share a common basis: the sum of IP and the external mechanical power (EP) is equal to the total mechanical power, as represented by net VO2....

Preliminary study: the effect of biomechanical foot orthotics in bilateral pedalling asymmetry in three cyclists affected by an anatomic asymmetry

The optimization of the cyclist's position aims to increase performance and may prevent injuries. To find the optimum posture, taking into account anthropometry of the cyclist is essential [1] because an anatomic asymmet...

Development of a multi-directional rating test method for bicycle frame stiffness

The methods for determining the bicycle frame stiffness exist in many forms. Because the stiffness measuring method is not standardized, each bicycle magazine or bicycle constructer uses his own test configuration. This...

The reliability and validity of the 3-minute critical power test

Background: Athletes utilise exercise testing to assist with training design and race strategy. Critical power (CP) is a useful addition to an exercise testing battery as it provides an estimate of the heavy-severe exerc...

Download PDF file
  • EP ID EP2801
  • DOI -
  • Views 561
  • Downloads 28

How To Cite

Daniel Taylor*, Mark F Smith, Veronica E Vleck (2012). Reliability of performance and associated physiological responses during simulated sprint-distance triathlon. Journal of Science and Cycling, 1(1), 21-29. https://europub.co.uk/articles/-A-2801