RESEARCH COMMON MODE REJECTION IN CONDUCTOMETRIC BIOSENSOR SYSTEM WITH DIFFERENTIAL SENSORS

Abstract

In the article are given theoretical and experimental evaluation of errors which arise due to incomplete suppression of common-mode noise on a differential sensor. The improved scheme of the measuring channel is suggested, its conversion feature studied and the possibility of diagnostic sensors is demonstrated. With using vector models evaluated the suppression of common mode noise for different pairs of transducer's parameters. Experimental confirmation of the theoretical estimates of possible levels of errors from common mode noise in the experimental measurement channels is given.

Authors and Affiliations

V. G. Melnyk, O. D. Vasilenko, A. Е. Dudchenko, V. D. Pogrebnyak

Keywords

Related Articles

DEVELOPMENT OF AN AMPEROMETRIC BIOSENSOR FOR THE ACETYLCHOLINE DETERMINATION IN BIOLOGICAL SAMPLES

The work is devoted to the development of amperometric biosensor for the determination of acetylcholine in biological samples. In the work, two different variants of co-immobilization of choline oxidase and acetylcholine...

EXCITON SPECTRA IN MULTI-SHELL OPEN SEMICONDUCTOR NANOTUBE

The purpose of this paper is the theoretical investigation of electron, hole and exciton spectral parameters in multi-shell open cylindrical semiconductor nanotube composed of the semiconductors and AsGaAlxx−1. All analy...

THERMOELECTRIC SENSORS FOR REGISTRATION OF INTRAOCULAR TEMPERATURE

To develop thermoelectric sensors for measuring of intraocular temperature and to study temperature distribution in different parts of the rabbit eye, depending on the ambient temperature. Materials and methods. The expe...

LIGHT ABSORPTION OF SMALL CDS QUANTUM DOTS

The aim of article is to analyze the conditions of the interface states arise which caused by the polarization trap, and determine the impact of these conditions on the light absorption. Therefore, it was determined the...

ELECTROMAGNETIC WAVES RADIATOR WITH CONTROLLED CHARACTERISTICS

The problem of Н-sectorial horn-type radiator parameter improvement – the width of the main directional lobe (DL), side lobe level reduction, DL form monitoring with the help of a covering of an internal radiator cavity...

Download PDF file
  • EP ID EP399717
  • DOI 10.18524/1815-7459.2014.3.108258
  • Views 71
  • Downloads 0

How To Cite

V. G. Melnyk, O. D. Vasilenko, A. Е. Dudchenko, V. D. Pogrebnyak (2014). RESEARCH COMMON MODE REJECTION IN CONDUCTOMETRIC BIOSENSOR SYSTEM WITH DIFFERENTIAL SENSORS. Сенсорна електроніка і мікросистемні технології, 11(3), 49-61. https://europub.co.uk/articles/-A-399717