Research Issues in DFIG Based Wind Energy System
Journal Title: Elektronika - Year 2018, Vol 22, Issue 1
Abstract
Among different renewable energy sources, Wind energy is the most imperative energy source in power system. The development of grid connected wind energy conversion system expands, its grid connectivity issues has additionally been expanded. A portion of the issues are incorporates, for example, the regulation of voltage at Point of Common Coupling (PCC), reactive power absorption and injection, voltage sag and swell and etc. The Doubly Fed Induction Generator (DFIG) is most broadly utilized as a part of wind energy conversion system. DFIGs are extremely sensitive to grid voltage disturbances. With expanded entrance of wind energy as a renewable energy source the wind turbine should be connected to the grid during transient conditions like grid faults. The Fault Ride-Through (FRT) or Low Voltage Ride Through (LVRT) capability of wind turbines during grid faults is one of the core requirements to ensure stability in the power grid during transients and fault conditions. In this paper consists of various grid connectivity issues and research areas of wind energy conversion system and also the various control schemes for improving the LVRT system. These several techniques are used to improve the LVRT capability and limit the fault current to avoid the disconnection of DFIG from the grid under fault conditions for enhancement of stability and the performance of wind turbine.
Authors and Affiliations
R. Rajasekaran, M. Mekala
An improved implementation of hierarchy array multiplier using CslA adder and full swing GDI logic
In this paper, an efficient implementation of a 16 bit array hierarchy multiplier using full swing Gate Diffusion Input (GDI) logic is discussed. Hierarchy multiplier is attractive because of its ability to carry the mul...
Single DD-DXCCII based quadrature oscillator with simultaneous current and voltage outputs
In this paper, a versatile quadrature oscillator using single Differential Difference Second Generation Dual-X Current Conveyor (DD-DXCCII) as an active element, two grounded capacitors and three grounded resistors is pr...
A Collaborative Framework for Avoiding Interference Between Zigbee and WiFi for Effective Smart Metering Applications
Energy management is one of the foremost priorities of research in many countries across the world. The introduction of modern information and communication technologies (ICT) are transforming the existing power grid, to...
Control Strategy for Cascaded Medium - High Voltage STATCOM
Control strategy is researched for cascaded medium high static synchronous compensator to provide synthetic compensation ability of reactive power, harmonics and asymmetric currents. Basing on selective harmonic compensa...
Drift Free Variable Step Size Perturb and Observe MPPT Algorithm for Photovoltaic Systems Under Rapidly Increasing Insolation
The characteristic of a Photovoltaic (PV) panel is most affected by the incident solar insolation temperature, shading, and array configuration. Maximum power point tracking (MPPT) algorithms have an important role in ha...