Preventive Thermographic Diagnostic of a HV Busbar Disconnector
Journal Title: Elektronika - Year 2016, Vol 20, Issue 1
Abstract
For the purpose of increasing quality, continuity and, at the same time, of increasing reliability and decreasing the losses in an electric power system (EPS), there is an emerging need for preventive diagnostic testing. From the standpoint of an electric power system availability, it is desirable to perform as many tests as possible without a violation of operating conditions of the system itself. The paper presents the thermographic testing of a HV disconnector, as an online testing with the aim of preventive maintenance and condition diagnosis of particular elements, as well as the suggestions for taking adequate measures with the aim of removing potential malfunctions. For the testing results to be quality and to give a reliable information, the load of a facility must be bigger that 50% of the nominal power. On the basis of obtained thermograms, the analysis of the disconnector and its contacts is performed, as well as of the contacts towards other elements in the facility.
Authors and Affiliations
Predrag Šaraba, Zoran Ljuboje, Božidar Popović, Dražan Krsmanović
Prototype of the Multichannel Acquisition System Developed for ICTM Pressure Transmitters
This paper presents a prototype of the multichannel acquisition unit AKV-100 developed for purposes of pressure and temperature measurements using proprietary ICTM pressure transmitters TPa-110 based on MEMS piezoresisti...
Control Strategy for Cascaded Medium - High Voltage STATCOM
Control strategy is researched for cascaded medium high static synchronous compensator to provide synthetic compensation ability of reactive power, harmonics and asymmetric currents. Basing on selective harmonic compensa...
Impact of Sectorization/Vehicular Traffic on Minimum Cell Size for Information Capacity Increase in Cellular Systems
In this paper results of mathematical analysis supported by simulation are used to study the impact of sectorization/vehicular traffic on the theoretical limit for cell size radius reduction in cellular wireless communic...
Influence of Signal Stationarity on Digital Stochastic Measurement Implementation
The paper presents the influence of signal stationarity on digital stochastic measurement method implementation. The implementation method is based on stochastic voltage generators, analog adders, low resolution A/D conv...
Low Voltage Mixed-mode Multi Phase Oscillator Using Single FDCCII
In this paper a new low voltage mixed-mode multiphase quadrature oscillator employing a single fully differential second generation current conveyor, two resistors and two grounded capacitors is proposed. The proposed ci...